跳转至内容
Merck
CN

Z-2183

ZytoLight® SPEC EWSR1/FLI1 TriCheck Probe

Green/Orange/Blue, pkg of 0.05 mL

别名:

Dual color probe, fluorochrome, probe

选择规格

变更视图

关于此项目

eCl@ss:
32150313
登录 查看您的价格
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


product line

ZytoVision

packaging

pkg of 0.05 mL, pkg of 5 tests

manufacturer/tradename

ZytoVision

storage condition

protect from light

color

, Green/Orange/Blue

application(s)

research use

storage temp.

2-8°C

General description

The ZytoLight® SPEC EWSR1/FLI1 TriCheck Probe (PL141) is a probe for for the qualitative detection of rearrangements involving the humanEWSR1 gene and the human FLI1 gene
The ZytoLight®SPEC EWSR1/FLI1 TriCheck Probe is composed of:

  • ZyGreen (excitation 503 nm/emission528 nm) labeled polynucleotides (~10ng/µl), which target sequences mappingin 22q12.2** (chr22:29,779,841-30,179,900) distal to the EWSR1 breakpoint region
  • ZyOrange (excitation 547 nm/emission 572 nm) labeled polynucleotides(~4.5 ng/µl), which target sequences mapping in 22q12.1-q12.2**(chr22:29,191,431-29,673,440) proximal to the EWSR1 breakpoint region
  • ZyBlue (excitation at 418 nm andemission 467 nm) labeled polynucleotides (~37 ng/µl), which target sequences mapping in 11q24.3**(chr11:128,707,454-129,346,602) distal to the FLI1 breakpoint region
  • Formamide based hybridization buffer
The fluorescence in situ hybridization (FISH) technique allows for the detection and visualization of specific nucleic acid sequences in cell preparations. Following DAPI counterstaining of the DNA, hybridized probe fragments are observed using a fluorescence microscope with filters tailored for the fluorochromes is used to label the FISH probe fragments.

Application

  • Differentiating Ewing sarcoma/PNET from classic neuroblastoma, Wilms tumor, and rhabdomyosarcoma is crucial.
  • The t(11;22)(q24;q12.2) translocation, which juxtaposes the EWSR1 gene at 22q12.2 next to the FLI1 locus, is the most frequent translocation involving the EWSR1 gene region.
  • Translocations in the 22q12.2 region are found in 90-95% of patients with Ewing sarcoma
  • Therefore, the ZytoLight® SPEC EWSR1/FLI1 TriCheck Probe is used to detect EWSR1 rearrangements by fluorescence in situ hybridization (FISH) to confirm the presence of Ewing sarcoma/PNET.

Analysis Note

  • In an interphase nucleus without a FLI1-EWSR1 rearrangement, two green/orange fusion signals and two blue signals are expected.
  • A FLI1-EWSR1 fusion is indicated by:
    • One separate orange signal co-localizing with one blue signal.
    • One separate green signal.
  • An EWSR1 translocation not involving FLI1 is indicated by:
    • The separation of one green/orange fusion signal.
    • No co-localization of the separated orange signal with one blue signal.

Legal Information

ZytoLight is a registered trademark of ZytoVision GmbH in Germany


象形图

Health hazard

警示词

Danger

危险代码

Hazard Classifications

Carc. 2 - Repr. 1B - STOT RE 2 Oral

靶器官

Blood

存储类别

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。