跳转至内容
Merck
CN

24256

SPB®-624毛细管GC色谱柱

L × I.D. 60 m × 0.25 mm, df 1.40 μm

别名:

SPB-624,60m,0.25mm,1.4μm

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

UNSPSC Code:
41115710
EC Number:
231-545-4
eCl@ss:
32119290
NACRES:
SB.54
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


material

fused silica

agency

EPA 524.2,0030,624,8260,OLM04.2 VOA, meets requirements for USP G43, suitable for EPA 601

parameter

≤25-250 °C temperature (isothermal or programmed)

Beta value

45

df

1.40 μm

technique(s)

gas chromatography (GC): suitable

L × I.D.

60 m × 0.25 mm

matrix active group

SPB 624

application(s)

environmental
food and beverages
pharmaceutical

column type

capillary intermediate polar

General description

应用:该色谱柱经过专门测试,可确保分离度、效率和低流失。它被设计用于环境样品中挥发性卤化、非卤化及芳香族污染物的吹扫捕集分析。
USP Code:该色谱柱符合 USP G43 要求。

  • 键合的
  • 所有权
温度限制
  • ≤0.32 mm 内径:亚常温至 250°C(等温或编程)
  • ≥0.53 mm 内径:亚常温至 230 °C(等温或编程)

Application

SPB®-64 fused silica capillary column may be used in gas chromatography quipped with flame ionization detector (FID) in order to measure styrene level in the blood and in the cochlear samples, in an investigation to determine the distribution of styrene in the cochlea, to monitor the hearing loss and death of cochlear cells in different regions as a result of varying styrene dosage and to analyse the relative vulnerability of cochlear cells and cell death pathways after styrene exposure as styrene is ototoxic and causes cochlear damage starting from the middle turn.

Other Notes

We offer a variety of chromatography accessories including analytical syringes

Legal Information

SPB is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under SPB®-624毛细管GC色谱柱


存储类别

13 - Non Combustible Solids

wgk

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库


相关内容

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.


Guang-Di Chen et al.
Toxicological sciences : an official journal of the Society of Toxicology, 98(1), 167-177 (2007-04-11)
It is known that styrene is ototoxic and causes cochlear damage starting from the middle turn. However, the cellular mechanism underlying styrene ototoxicity is still unclear. In this study, rats were exposed to styrene by gavage at different doses once



全球贸易项目编号

货号GTIN
41920-1G-F04061825591483
41920-5G-F04061831820249
2425604061833659236