InChI key
AUHZEENZYGFFBQ-UHFFFAOYSA-N
InChI
1S/C9H12/c1-7-4-8(2)6-9(3)5-7/h4-6H,1-3H3
SMILES string
Cc1cc(C)cc(C)c1
grade
analytical standard
vapor density
4.1 (vs air)
vapor pressure
14 mmHg ( 55 °C), 2.49 mmHg ( 25 °C)
autoignition temp.
1022 °F
expl. lim.
0.88-6.1 %, 100 °F
packaging
ampule of 1000 mg
technique(s)
HPLC: suitable, gas chromatography (GC): suitable
bp
163-166 °C (lit.)
mp
−45 °C (lit.)
density
0.864 g/mL at 25 °C (lit.)
application(s)
environmental
signalword
Danger
Hazard Classifications
Acute Tox. 4 Inhalation - Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 3 - Skin Irrit. 2 - STOT SE 3
target_organs
Respiratory system
存储类别
3 - Flammable liquids
wgk
WGK 2
flash_point_f
122.0 °F
flash_point_c
50 °C
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
Michael Cushion et al.
Dalton transactions (Cambridge, England : 2003), (9)(9), 1632-1635 (2009-05-08)
The new sterically encumbered facially coordinating N(3)-donor ligand cis,cis-1,3,5-tris(mesitylideneimino)cyclohexane (L1) has been synthesised. Reaction with [Cu(NCCH(3))(4)]PF(6) gives [Cu(L1)NCCH(3)]PF(6) (1), the bound acetonitrile being labile and readily replaced by CO to yield [Cu(L1)CO]PF(6) (2); both 1 and 2 have been structurally
M Prager et al.
Physical chemistry chemical physics : PCCP, 7(13), 2587-2593 (2005-09-29)
Mesitylene can be stabilized at He temperature in three solid phases of so far unknown crystal structures. Rotational tunneling of methyl groups is based on rotational potentials and used to characterize structural aspects. In phase III found after the first
Dorota Wiaderna et al.
International journal of occupational medicine and environmental health, 15(4), 385-392 (2003-03-01)
Trimetylbenzene isomers: pseudocumene, hemimellitene and mesitylene, are major components of numerous commercial solvents and high-grade fuels. In our earlier research on rats we have proved that inhalation exposure to pseudocumene or hemimellitene at concentrations close to the MAC value results
Toshifumi Dohi et al.
Chemical communications (Cambridge, England), (40)(40), 4152-4154 (2007-10-11)
We have found that the use of fluoroalcohol media greatly enhanced the efficiency and scope of the direct dehydrative condensation of arenes and hypervalent iodine(III) compounds; the present clean method has a broad range of applicability as well as unique
Sanyog Sharma et al.
Organic & biomolecular chemistry, 11(4), 654-661 (2012-12-12)
Two mesitylene based probes, having catechol/phenol units in conjunction to the Schiff base have been synthesized. The probe with a catechol unit can be used to sense and discriminate between F(-) and CN(-) through different colorimetric and fluorimetric responses using
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持