跳转至内容
Merck
CN

53572-U

Ascentis® Express 160 Å PFAS (2.7 μm) Delay HPLC Columns

L × I.D. 5 cm × 3.0 mm, HPLC Delay Column; suitable for PFAS testing

别名:

Ascentis® Express 160 Å PFAS Delay, 2.7 μm HPLC Column

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

UNSPSC Code:
41115709
NACRES:
SB.52
Particle size:
2.7 μm
Matrix active group:
PFAS, highly retentive endcapped silane bonding phase
Pore size:
160 Å pore size
Matrix:
Fused-Core® silica particle platform particle platform, superficially porous particle
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


产品名称

Ascentis® Express 160 Å PFAS (2.7 μm) Delay HPLC Columns, suitable for PFAS testing, column L × I.D. 5 cm × 3.0 mm

material

stainless steel column

Quality Segment

agency

suitable for ASTM® 7968, suitable for ASTM® 7979, suitable for DIN 38407-42, suitable for EPA 533, suitable for EPA 537.1, suitable for EPA 8327, suitable for EPA ACB B21-02, suitable for EPA ACB B23-05b, suitable for EPA OTM-45, suitable for GB 31604.35-2016, suitable for GB 5009.253-2016, suitable for ISO 21675 2019, suitable for ISO 25101, suitable for ISO/CEN 15968-2010, suitable for USP L62

reg. compliance

suitable for FDA C-010.02

product line

Ascentis®

feature

endcapped

packaging

1 ea of

parameter

≤60 °C temp. limit, ≤9000 psi max. pressure (600 bar)

technique(s)

HPLC: suitable, LC/MS: suitable

column L × I.D.

5 cm × 3.0 mm

surface area

90 m2/g

matrix

Fused-Core® silica particle platform particle platform, superficially porous particle

matrix active group

PFAS, highly retentive endcapped silane bonding phase

particle size

2.7 μm

pore size

160 Å pore size

operating pH range

2-9

application(s)

PFAS testing

separation technique

reversed phase

General description

Ascentis® Express PFAS Delay is a high-performance liquid chromatography column based on Fused-Core® particle design. The highly retentive endcapped silane of the Ascentis® Express PFAS Delay column provides high retention of PFAS compounds across various mobile phase conditions and is used to delay background instrument PFAS contamination from interference with analyzed samples. For this reason, the Ascentis® Express PFAS Delay column is placed upstream of the sample injector.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.


Still not finding the right product?




历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库