跳转至内容
Merck
CN

CRM43551

氯普芬

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

别名:

N-3-氯苯氨基甲酸异丙酯, 氯-ICP, 氯普芬

登录 查看组织和合同定价。

选择尺寸


关于此项目

线性分子式:
C10H12NO2Cl
化学文摘社编号:
分子量:
213.66
NACRES:
NA.24
UNSPSC Code:
41116107
Beilstein/REAXYS Number:
2211397
MDL number:
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

产品名称

氯普芬, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

SMILES string

CC(C)OC(=O)Nc1cccc(Cl)c1

InChI

1S/C10H12ClNO2/c1-7(2)14-10(13)12-9-5-3-4-8(11)6-9/h3-7H,1-2H3,(H,12,13)

InChI key

CWJSHJJYOPWUGX-UHFFFAOYSA-N

grade

certified reference material
TraceCERT®

product line

TraceCERT®

shelf life

limited shelf life, expiry date on the label

manufacturer/tradename

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

format

neat

storage temp.

2-8°C

Quality Level

正在寻找类似产品? 访问 产品对比指南

相关类别

Application

The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
Chlorpropham CRM may also be used as given below:

  • Determining chlorpropham residues in concrete samples using high-performance liquid chromatography (HPLC) combined with a UV-Visible detector to evaluate the concentration of chlorpropham lost to the concrete flooring during potatoes storage
  • Analysis of chlorpropham in different parts of potato by a state-of-the-art microextraction (µQuEChERS), followed by a clean-up based on dispersive solid-phase extraction and ultra-high performance liquid chromatography combined with photodiode array detection(UHPLC-PDA)
  • Investigate the wastewater and products of three vegetable and two potato processing companies for the presence of pesticide residues using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI)
  • Simultaneous analysis of 171 pesticide residues in cowpea samples using reversed-dispersive solid-phase extraction (r-DSPE) based on the use of multi-walled carbon nanotubes (MWCNTs) as a sorbent for sample clean-up and gas chromatography-tandem mass spectrometry (GC-MS/MS)
  • To develop a dispersive liquid-liquid microextraction(DLLME) coupled with gas chromatography-mass spectrometry procedure for the extraction and quantification of 40 pesticide residues in nutraceutical samples
  • Development and validation of a multi-residue procedure for the determination of 109 pesticides from different chemical classes in 345 tomato samples based on modified QuEChERs sample preparation combined with liquid chromatography tandem mass spectrometry (LC-MS/MS)

General description

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com

Chlorpropham is a mitosis inhibitor that belongs to the class of carbamate herbicides and plant growth regulators. It interferes with the spindle microtubules organization leading to the formation of multiple spindles and nuclei. A selective and systemic herbicide, it is used for the pre-emergence control of annual grass and some broad-leaved weeds in onions, leeks, garlic, shallots, alfalfa, clover, sugar beets, spinach, lettuce, endive, chicory, herbs, peas, beans, carrots, celery, black salsify, fennel, soybeans, cotton, rice, safflowers, sunflowers, cranberries, cane berries, ornamentals, and shrubs, perennial grass seed crops. It also finds its use to prevent post-harvest sprouting in potatoes.
According to the Commission Implementing Regulation (EU) No 2019/989 of 17th June 2019, chlorpropham is not approved for use in the European Union (EU) as a plant protection agent, following the Regulation (EC) No. 1107/2009. But maximum residue levels of 0.01- 0.05 mg/kg are allowed for its presence in the products of plant and animal origin as per the EU Reg. 2021/155.

Other Notes

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Warning

Hazard Classifications

Acute Tox. 4 Oral - Aquatic Chronic 2 - Carc. 2 - STOT RE 2

存储类别

11 - Combustible Solids

wgk

WGK 2

flash_point_f

Not applicable

flash_point_c

Not applicable

法规信息

农药列管产品
此项目有

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持