KGEPA1ZTT1
Millipore Express® SHF 0.2µm, Opticap® XLT 10 Capsule
Fittings 1-1/2 in. TC w/ gauge port, Autoclavable
Product Name
Millipore Express® SHF, Opticap® XLT Capsule, Opticap® XLT, cartridge nominal length 10 in. (25 cm), filter diam. 10.7 cm (4.2 in.)
material
polyethersulfone membrane
polypropylene housing
polypropylene support
polypropylene vent cap
silicone O-ring
silicone seal
Quality Level
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
Sterilization Compatibility
autoclavable compatible
product line
Opticap® XLT
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
1 bar max. differential pressure (15 psi) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
2.8 bar max. inlet pressure (40 psi) at 60 °C
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
technique(s)
sterile filtration: suitable
L
38.1 cm (15.0 in.)
W
7.8 in.
cartridge nominal length
10 in. (25 cm)
device size
10 in.
filter diam.
10.7 cm (4.2 in.)
filter filtration area
0.54 m2
impurities
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
matrix
Millipore Express® SHF
pore size
0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water at 23 °C
fitting
38 mm (1 1/2 in.) inlet sanitary flange
38 mm (1 1/2 in.) outlet sanitary flange
Looking for similar products? Visit Product Comparison Guide
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min at 126 °C; not in-line steam sterilizable
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Regulatory Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service