Select a Size
About This Item
Product Name
Opticap® XLT 10 CapsuleMedia: Millipore Express® SHC 0.5 / 0.2 µm, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1-1/2 in. Sanitary FlangeT-line with 1-1/2 in. Gauge PortMax Operating Pressure: 80 psi @ 25 °C
Quality Level
material
polyester support, polypropylene device, polypropylene housing, polypropylene vent cap, polysulfone device, silicone seal
reg. compliance
meets FDA 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XLT 10
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
1.0 bar max. inlet pressure (15 psi) at 80 °C, 1000 mbar max. differential pressure (15 psi) at 80 °C (Forward), 2.75 bar max. inlet pressure (40 psi) at 60 °C, 2100 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent), 25 °C max. inlet temp., 5.5 bar max. inlet pressure (80 psi) at 25 °C, 5500 mbar max. differential pressure (80 psi) at 25 °C (Forward), 6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent), 6900 mbar max. differential pressure (100 psi) at 25 °C (Forward; intermittent), 80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
L
15.0 in.
W
7.8 in.
cartridge nominal length
10 in. (25 cm)
device size
10 in.
filter diam.
14.5 cm (5.7 in.)
filter filtration area
0.54 m2
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
matrix
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water
fitting
(38 mm (1½ in.) Sanitary Flange Inlet and Outlet)
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min at 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Still not finding the right product?
Explore all of our products under Opticap® XLT 10 CapsuleMedia: Millipore Express® SHC 0.5 / 0.2 µm
Regulatory Information
This item has
Stay compliant with GMP using the Emprove® Program
Accelerate qualification, maintain compliance, and save time with Emprove® Dossiers.
Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.
Register for free and access Emprove® Dossiers within minutes. Upgrade your subscription plan to unlock advanced and customized content in the Emprove® Suite
Not finding what you are looking for? Visit the Emprove® Program Help page.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Our regional filter supply model ensures reliable, consistent, and secure supply of high-quality filters for biomanufacturing.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| KHGEG1STT1 | 04053252486104 |