KHGES003FH3
Millipore Express® SHC 0.5/0.2µm, Opticap® XL 300 Capsule
Fittings 3/4 in. TC- 9/16 in. HB, Sterile
Synonym(s):
Opticap Sterile XL 300 Millipore Express SHC 0.5/0.2 μm 3/4 in. TC-9/16 in. HB
Product Name
Millipore Express® SHC, Opticap® XL Capsule, sterile, Opticap® XL, inlet connection diam. 3/4 in., pore size 0.5/0.2 μm, cartridge nominal length 4.7 in. (11.9 cm)
material
polyester support
polyethersulfone membrane
polypropylene housing
polypropylene vent cap (Gamma stable)
silicone O-ring (gamma-stable)
silicone seal
Quality Level
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
sterile
Sterilization Compatibility
autoclavable compatible
product line
Opticap® XL
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
1.0 bar max. differential pressure (15 psi) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
2.8 bar max. inlet pressure (40 psi) at 60 °C
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
technique(s)
sterile filtration: suitable
L
11.9 cm (4.7 in.)
cartridge nominal length
4.7 in. (11.9 cm)
diam.
5.6 cm (2.2 in.)
filtration area
0.029 m2 (0.316 ft2)
inlet connection diam.
3/4 in.
inlet to outlet W
11.9 cm (4.7 in.)
outlet connection diam.
9/16 in.
impurities
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
matrix
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water at 23 °C
fitting
19 mm (3/4 in.) inlet sanitary flange
14 mm (9/16 in.) outlet hose barb
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 2.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Disclaimer
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service