About This Item
Product Name
Opticap® XLT 20 CapsuleMedia: Sterile Millipore Express® SHC 0.5 / 0.2 µm, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1-1/2 in. Sanitary FlangeT-line with 1-1/2 in. Gauge PortMax Operating Pressure: 80 psi @ 25 °C
Quality Level
material
polyester support, polypropylene device, polypropylene housing, polypropylene vent cap, polysulfone device, silicone seal
reg. compliance
meets FDA 21 CFR 177-182 (all component materials)
sterility
irradiated, sterile
product line
Opticap® XLT 20
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
1.0 bar max. inlet pressure (15 psi) at 80 °C, 1000 mbar max. differential pressure (15 psi) at 80 °C (Forward), 2.75 bar max. inlet pressure (40 psi) at 60 °C, 2100 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent), 25 °C max. inlet temp., 5.5 bar max. inlet pressure (80 psi) at 25 °C, 5500 mbar max. differential pressure (80 psi) at 25 °C (Forward), 6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent), 6900 mbar max. differential pressure (100 psi) at 25 °C (Forward; intermittent), 80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
cartridge nominal length
20 in. (50 cm)
device L
62.5 cm (24.6 in.)
device size
20 in.
filter diam.
19.8 cm (7.8 in.)
filter filtration area
1.09 m2
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
matrix
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water
fitting
(38 mm (1½ in.) Sanitary Flange Inlet and Outlet)
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min at 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Still not finding the right product?
Explore all of our products under Opticap® XLT 20 CapsuleMedia: Sterile Millipore Express® SHC 0.5 / 0.2 µm
Regulatory Information
This item has
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| KHGES2STT1 | 04053252604096 |