Merck
CN
  • [Preparation of new solid-phase microextraction fiber based on cucurbit[7] uril coordination polymers and its application in determination of polycyclic aromatic hydrocarbons from environmental water samples].

[Preparation of new solid-phase microextraction fiber based on cucurbit[7] uril coordination polymers and its application in determination of polycyclic aromatic hydrocarbons from environmental water samples].

Se pu = Chinese journal of chromatography (2015-04-24)
Lifen Yan, Yan Lü, Lin Shao, Qingdi Zhou, Nan Dong
ABSTRACT

A novel solid-phase microextraction fiber was prepared via simple adhesion process. Fused-silica fiber was used as supporting substrate and the cucurbit[7] uril/Eu coordination polymers induced by [CdCl4]2- anion was affixed onto the surface of fused-silica fiber with high-temperature epoxy resin as a sorbent coating. The SPME coating was characterized by scanning electron microscopy and thermal analysis. Coupled to gas chromatography, the fiber was used to extract polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Analytical performances of the proposed method were investigated under the optimum extraction conditions (extraction temperature, 75 °C; mass concentration of NaCl, 200 g/L; extraction time, 40 min; desorption time, 2 min; desorption temperature, 250 °C) compared with commercial fibers for the same analytes. For the seven PAHs (naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene and pyrene), good linearity was obtained ranging from 1 µg/L to 1000 µg/L. Limits of detection were 0.29-2.09 µg/L with the RSDs no more than 8.6%. The established SPME-GC method was applied to determine the spiked PAHs in real river water samples and satisfactory results were obtained with recoveries between 97. 2% and 109. 0%. Under the optimal conditions, the extraction effect of home-made coating was similar to the commercial PDMS (polydimethylsiloxane) coating, which further confirmed its potential in the solid-phase microextraction.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME-OC Fiber Assembly, Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 75 μm(Coating thickness includes 65 μm coating + 10 μm OC (overcoating), needle size 23 ga, pkg of 3 ea, fiber L 1 cm
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME Sampling Stand, for use with 15 mL vials
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
SPME Portable Field Sampler, coating PDMS
Supelco
SPME Portable Field Sampler, coating CAR/PDMS
Supelco
SPME Portable Field Sampler, coating PDMS/DVB
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 30 μm(PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 30 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), metal alloy fiber, df 100 μm(PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assortment kit 1, for use with autosampler, needle size 24 ga
Supelco
SPME fiber assortment kit 2, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assortment kit 4, for use with autosampler, size 24 ga
Supelco
SPME StableFlex fiber assortment kit, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assortment kit 2, for use with manual holder, needle size 24 ga
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assortment kit 1, for use with manual holder, needle size 24 ga
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga, metal alloy fiber
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
SPME fiber assortment kit 2, for use with autosampler, size 24 ga