  • Improvement in 8h-sampling rate assessment considering meteorological parameters variability for biogas VOC passive measurements in the surroundings of a French landfill.

Improvement in 8h-sampling rate assessment considering meteorological parameters variability for biogas VOC passive measurements in the surroundings of a French landfill.

Talanta (2015-10-11)
Marie Verriele, Nadine Allam, Laurence Depelchin, Laurence Le Coq, Nadine Locoge
ABSTRACT

Passive sampling technology has been extensively used for long-term VOC atmospheric concentrations' monitoring. Its performances regarding the short-term measurements and related to VOC from biogas were evaluated in this work: laboratory scale experiments have been conducted in order to check the suitability of Radiello® diffusive samplers for the assessment of 8 h-VOC levels in highly changeable meteorological conditions; in a second step a short pilot field campaign was implemented in the vicinity of a West-French landfill. First of all, it was assessed that amongst a diversified list of 16 characteristic compounds from biogas, mercaptans, some halogenated, oxygenated compounds and terpenes could not be measured accurately by this passive technique either because they are not captured by the sorbent or they are not quantitatively desorbed in the chosen mediated analytical conditions. Moreover, it has been confirmed that sampling rates (SR) related to isopentane, THF, cyclohexane, toluene, p-xylene and n-decane are influenced by environmental factors: the main influence concerns the wind speed. From 2 m s(-1), when the velocity increases by 1 m s(-1), the SR increases from 12 to 32% depending on the COV (considering a linear dependence between 2 and 7 m s(-1)). Humidity has no effect on SR, and temperature influence is rather limited to less than 3% per degree. A comprehensive uncertainty estimation, including uncertainties linked to meteorological changes, has led to global relative uncertainties comprising between 18% and 54% from one VOC to another: a quite high value comparatively to those obtained without considering meteorological condition influences. To illustrate our results, targeted VOC were quantified in the field, on a single day: concentrations range between LD to 3 µg m(-3): relatively very low concentrations compared to those usually reported by literature.

MATERIALS
Product Number
Brand
Product Description

Supelco
radiello Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Supelco
radiello BTEX Calibration Kit (CS2 Desorption)
radiello BTEX/VOC Starter Kit, Thermal Desorption
radiello Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
radiello On-Field Thermometer, Reader, pk of 1
radiello Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
radiello Diffusive Bodies, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello Filtration Kit, pk of 20
Supelco
radiello BTEX Calibration Kit (Thermal Desorption)
radiello Clips, suspending Radiello triangular support plate, pk of 20
radiello BTEX/VOC Starter Kit, CS2 Desorption
radiello Diffusive Bodies, white, configured for general use, pk of 20
radiello 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
radiello Diffusive Bodies, yellow, configured for reduced sampling rates, pk of 20
radiello On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello Hydrogen Sulfide Starter Kit
radiello Barcode Labels, pk of 198
radiello Anesthetic Gases and Vapor Sampler
radiello Cartridge Adsorbents, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello Outdoor Shelter, pk of 10
radiello Cartridge Adsorbents, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello Replacement Mounting Strips, for use with Radiello Outdoor Shelter, pk of 100
radiello Cartridge Adsorbents, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
radiello Cartridge Adsorbents, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
radiello Triangular Support Plate, pk of 20
radiello Vertical Adapter, threaded for standard use, pk of 20
radiello Cartridge Adsorbents, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20