Skip to Content
Merck
CN
  • Direct spectrophotometric determination of ferbam (Iron(III) dimethyldithiocarbamate) in commercial sample and wheat grains using 4,7-diphenyl-1,10-phenanthroline.

Direct spectrophotometric determination of ferbam (Iron(III) dimethyldithiocarbamate) in commercial sample and wheat grains using 4,7-diphenyl-1,10-phenanthroline.

Journal of agricultural and food chemistry (2001-01-16)
A K Malik
ABSTRACT

A procedure has been developed for the determination of iron(III) dimethyldithiocarbamate by converting it into the iron(II)-bathophenanthroline complex, which is then dissolved in acetone-water (1:1), and the absorbance is measured at 534 nm against a reagent blank. Beer's law is obeyed over the concentration range 0.5-20 microg x mL(-1) in the final solution. The method is sensitive and highly selective and is used for the direct determination of ferbam in a commercial sample and in mixtures with various dithiocarbamates (ziram, zineb, maneb, etc.) and from wheat grains.