Skip to Content
Merck
CN
  • GC-MS analysis of organic acids in human urine in clinical settings: a study of derivatization and other analytical parameters.

GC-MS analysis of organic acids in human urine in clinical settings: a study of derivatization and other analytical parameters.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-02-01)
Chrysoula Christou, Helen G Gika, Nikolaos Raikos, Georgios Theodoridis
ABSTRACT

In the current paper the analytical conditions for the determination of ten free organic acids by GC-MS are studied with the aim to establish a method for organic acid profiling in human urine to be used as a tool for the detection of metabolic or other health disorders. Studies included the GC-MS method development, the derivatization (trimethylsilylation) reaction conditions, the stability of the standard solutions during storage in the freezer, and the stability of the formed trimethylsilyl derivatives. Best results were obtained at a derivatization temperature of 50°C, and a reaction time of 30 min. Standard solutions were stable for 22 days, derivatized samples were stable at least for 30 h when stored at -24°C. GC-MS analysis achieved sensitive determination of the organic acids under study with limits of detection ranging from 0.03 mmol/mol creatinine for glutaric acid, to 0.34 mmol/mol creatinine for glycolic acid. Within-day and day-to-day assay imprecision was found satisfactory with relative standard deviations being below 10%. The developed method was successfully applied to the quantitative analysis of free organic acids in urine samples obtained from hospitalized children. Creatinine-corrected excretion rates of all analyzed organic acids were within reference intervals.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium sulfate, BioXtra, ≥99.0%
Supelco
N,O-Bis(trimethylsilyl)trifluoroacetamide with trimethylchlorosilane, with 1% trimethylchlorosilane, derivatization grade (GC derivatization), LiChropur
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, analytical standard
Sigma-Aldrich
Chlorotrimethylsilane, puriss., ≥99.0% (GC)
Sigma-Aldrich
Sodium sulfate, BioUltra, anhydrous, ≥99.0% (T)
Sigma-Aldrich
Sodium sulfate, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Sodium sulfate, ACS reagent, ≥99.0%, anhydrous, granular
Sigma-Aldrich
Sodium sulfate, tested according to Ph. Eur., anhydrous
Sigma-Aldrich
Sodium sulfate, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, ≥99%
Sigma-Aldrich
Sodium sulfate, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99%
Sigma-Aldrich
Sodium sulfate, ACS reagent, ≥99.0%, anhydrous, powder
Sigma-Aldrich
Sodium sulfate, ≥99.99% trace metals basis
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Chlorotrimethylsilane, derivatization grade (GC derivatization), LiChropur, ≥99.0% (GC)
Sigma-Aldrich
Chlorotrimethylsilane, Wacker Chemie AG, ≥99.0% (GC)
Sigma-Aldrich
Chlorotrimethylsilane, purified by redistillation, ≥99%
Sigma-Aldrich
Chlorotrimethylsilane, ≥98.0% (GC)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Supelco
N,O-Bis(trimethylsilyl)trifluoroacetamide with trimethylchlorosilane, derivatization grade (GC derivatization), LiChropur, contains 10% TMCS, 98% (excluding TMCS)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%