Skip to Content
Merck
CN

The removal of Triton X-100 by dialysis is feasible!

Analytical and bioanalytical chemistry (2014-11-27)
Stefan Opitz, Franziska Hannika, Thomas Krüger, Heidrun Rhode
ABSTRACT

Triton X-100 has been widely used in many analytical and preparative protocols for a long time. Nevertheless, mass spectrometry, chromatographic separation, and spectrophotometric readout may be considerably hampered by this detergent due to signal suppression, complex formation, and high blank values, respectively. Additionally, Triton X-100 is not safe to remove prior to analytics. Here, microdialysis is introduced as a parallelizable, high-throughput method to clean samples from Triton X-100 with high efficacy and precision. To achieve this, we exploit the potential to considerably increase the critical micellar concentration of Triton X-100 by alteration of matrix properties. To that end, addition of several chaotropic compounds and organic solvents has been shown to increase the critical micellar concentration as well as the removal rate of the detergent. For application, matrix additives can be selected for analyte stability requirements out of a variety of compounds. Conveniently, all these additives are removable subsequently using the same microdialysis tool for downstream analytics requirements. Applicability and protocols are shown with proteomic sample preparation of purified proteins and complex protein mixtures prior to matrix-assisted laser desorption ionization (MALDI) mass spectrometry.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, anhydrous, 99.8%
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Water, PCR Reagent
Sigma-Aldrich
Ethanol Fixative 80% v/v, suitable for fixing solution (blood films)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Ethanol, absolute, denaturated with 0.5-1.5 Vol.% 2-butanone and approx. 0.001% Bitrex (GC), ≥98% (GC)
USP
1-Propanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
USP
Dehydrated Alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Supelco
Water, for ultratrace analysis, ACS reagent
Sigma-Aldrich
Water, Deionized
Supelco
DL-Dithiothreitol solution, 1 M in H2O
Sigma-Aldrich
Water, BioPerformance Certified
Sigma-Aldrich
Methanol, purification grade, 99.8%
Supelco
Density Standard 998 kg/m3, H&D Fitzgerald Ltd. Quality
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Water, tested according to Ph. Eur.
Pure Water Density Standard, UKAS ISO/IEC17025 and ISO Guide 34 certified, density: 0.9982 g/mL at 20 °C, density: 0.9970 g/mL at 25 °C
Sigma-Aldrich
Water, suitable for HPLC
Millipore
Urea solution, suitable for microbiology, 40% in H2O
Sigma-Aldrich
Urea solution, BioUltra, ~8 M in H2O
Sigma-Aldrich
Urea-12C, 99.9 atom % 12C
Sigma-Aldrich
Urea solution, 40 % (w/v) in H2O
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Isopropyl alcohol, ≥99.7%, FCC, FG
Sigma-Aldrich
1-Propanol, suitable for HPLC, ≥99.9%