Skip to Content
Merck
CN
  • Enhancement of specificity of aldosterone measurement in human serum and plasma using 2D-LC-MS/MS and comparison with commercial immunoassays.

Enhancement of specificity of aldosterone measurement in human serum and plasma using 2D-LC-MS/MS and comparison with commercial immunoassays.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-09-24)
Julie A Ray, Mark M Kushnir, John Palmer, Seyed Sadjadi, Alan L Rockwood, A Wayne Meikle
ABSTRACT

Accurate measurement of aldosterone is important for the standardized testing of primary hyperaldosteronism. Commercial immunoassays show substantial between-method variations resulting in significant clinical consequences. We developed a specific two dimensional (2D)-LC-MS/MS method for measuring aldosterone in human serum and plasma and compared it with three commercial immunoassays and an LC-MS/MS method. 250 μL samples, controls and calibrators spiked with d4-aldosterone were subjected to liquid-liquid extraction. The samples were analyzed using negative mode electrospray and 2D-LC followed by MS detection using an ABSciex 5500 mass spectrometer and compared with immunoassays of Siemens (Coat-A-Count), DiaSorin (CLIA-LIAISON), and IBL (ELISA). Data was acquired using multiple reaction-monitoring mode. LOQ and LOD of the method were 0.04 and 0.02 nmol/L respectively. The assay was linear up to 166 nmol/L. Inter and intra-assay imprecision at 0.13, 1.38 and 8.30 nmol/L were <10%. Interferences were absent and no differences were observed between serum and plasma matrices. Method recovery ranged from 95% to 113%. Ion suppression was not observed. Evaluated immunoassays showed positive biases ranging between 22% and 37% when compared with the developed method. We developed and validated an accurate method for measurement of aldosterone in human serum and plasma using 2D-LC-MS/MS which is suitable for clinical purposes. The method is faster than previously published LC-MS/MS methods, uses less sample, has adequate sensitivity while being able to preserve high specificity in a cost effective manner. Linearity of the assay makes it promising for urine and adrenal venous samples. Comparison with three commercial immunoassays demonstrates the advantages of the developed method.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate solution, Molecular Biology, 7.5 M
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
tert-Butyl methyl ether, anhydrous, 99.8%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Supelco
Methanol, analytical standard
Supelco
tert-Butyl methyl ether, analytical standard
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
tert-Butyl methyl ether, puriss. p.a., ≥99.5% (GC)
Sigma-Aldrich
Ammonium acetate, Vetec, reagent grade, 97%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
tert-Butyl methyl ether, reagent grade, 98%
Sigma-Aldrich
tert-Butyl methyl ether, suitable for HPLC, ≥99.8%
Supelco
tert-Butyl Methyl Ether, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
tert-Butyl methyl ether, reagent grade, ≥98%
Sigma-Aldrich
tert-Butyl methyl ether, ACS reagent, ≥99.0%
Sigma-Aldrich
tert-Butyl methyl ether, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material