Skip to Content
Merck
CN
  • Liquid chromatography tandem mass spectrometry determination of selected synthetic cathinones and two piperazines in oral fluid. Cross reactivity study with an on-site immunoassay device.

Liquid chromatography tandem mass spectrometry determination of selected synthetic cathinones and two piperazines in oral fluid. Cross reactivity study with an on-site immunoassay device.

Journal of chromatography. A (2014-12-09)
Ana de Castro, Elena Lendoiro, Hadriana Fernández-Vega, Stefan Steinmeyer, Manuel López-Rivadulla, Angelines Cruz
ABSTRACT

Since the past few years, several synthetic cathinones and piperazines have been introduced into the drug market to substitute illegal stimulant drugs such as amphetamine and derivatives or cocaine due to their unregulated situation. These emerging drugs are not usually included in routine toxicological analysis. We developed and validated a LC-MS/MS method for the determination of methedrone, methylone, mephedrone, 3,4-methylenedioxypyrovalerone (MDPV), fluoromethcathinone, fluoromethamphetamine, 1-(3-chlorophenyl)piperazine (mCPP) and 3-trifluoromethylphenylpiperazine (TFMPP) in oral fluid. Sample extraction was performed using Strata X cartridges. Chromatographic separation was achieved in 10min using an Atlantis(®) T3 column (100mm×2.1mm, 3μm), and formic acid 0.1% and acetonitrile as mobile phase. The method was satisfactorily validated, including selectivity, linearity (0.2-0.5 to 200ng/mL), limits of detection (0.025-0.1ng/mL) and quantification (0.2-0.5ng/mL), imprecision and accuracy in neat oral fluid (%CV=0.0-12.7% and 84.8-103.6% of target concentration, respectively) and in oral fluid mixed with Quantisal™ buffer (%CV=7.2-10.3% and 80.2-106.5% of target concentration, respectively), matrix effect in neat oral fluid (-11.6 to 399.7%) and in oral fluid with Quantisal™ buffer (-69.9 to 131.2%), extraction recovery (87.9-134.3%) and recovery from the Quantisal™ (79.6-107.7%), dilution integrity (75-99% of target concentration) and stability at different conditions (-14.8 to 30.8% loss). In addition, cross reactivity produced by the studied synthetic cathinones in oral fluid using the Dräger DrugTest 5000 was assessed. All the analytes produced a methamphetamine positive result at high concentrations (100 or 10μg/mL), and fluoromethamphetamine also at low concentration (0.075μg/mL).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Potassium chloride, ACS reagent, 99.0-100.5%
Sigma-Aldrich
Potassium chloride, AnhydroBeads, −10 mesh, 99.99% trace metals basis
Sigma-Aldrich
Ammonia-14N, 99.99 atom % 14N
Sigma-Aldrich
Potassium chloride, puriss. p.a., ≥99.5% (AT)
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Sodium hydroxide solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Sodium hydroxide solution, BioUltra, Molecular Biology, 10 M in H2O
Sigma-Aldrich
Sodium hydroxide, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
Sodium hydroxide, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Supelco
Sodium hydroxide solution, 49-51% in water, eluent for IC
Sigma-Aldrich
Sodium hydroxide solution, 50% in H2O
Sigma-Aldrich
Sodium hydroxide, reagent grade, 97%, flakes
Sigma-Aldrich
Sodium hydroxide, BioUltra, suitable for luminescence, ≥98.0% (T), pellets
Sigma-Aldrich
Sodium hydroxide, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Sodium hydroxide, beads, 16-60 mesh, reagent grade, 97%
Sigma-Aldrich
Sodium hydroxide, puriss. p.a., ACS reagent, K ≤0.02%, ≥98.0% (T), pellets
Sigma-Aldrich
Sodium hydroxide solution, purum, ≥32%
Sigma-Aldrich
Sodium hydroxide, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Sodium hydroxide solution, 5.0 M
Sigma-Aldrich
Sodium hydroxide, reagent grade, 97%, powder
Sigma-Aldrich
Sodium hydroxide, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Supelco
Potassium chloride solution, conductance standard C acc. to ISO 7888, 0.001 M KCl
Sigma-Aldrich
Boric acid-11B, ≥99 atom % 11B
Supelco
Potassium chloride solution, conductance standard A acc. to ISO 7888, 0.1 M KCl
Supelco
Potassium chloride solution, conductance standard B acc. to ISO 7888, 0.01 M KCl
Supelco
Potassium Chloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
3-Ethyl-2,4-pentanedione, mixture of tautomers, 98%