Skip to Content
Merck
CN
  • Development of a capillary electrophoretic method for determination of plasma clearance of iohexol in dogs and cats.

Development of a capillary electrophoretic method for determination of plasma clearance of iohexol in dogs and cats.

Biomedical chromatography : BMC (2014-08-12)
Alexander Hellqvist, Reidun Heiene, Siegrid De Baere, Siska Croubels, Ylva Hedeland
ABSTRACT

Renal function can be monitored by estimation of the glomerular filtration rate (GFR), for example, through measurement of the plasma clearance of a marker that is freely filtrated through the kidney without reabsorption. It has been proposed that iohexol is the most accurate marker for GFR determination in cats and dogs. However, there is a need for a validated capillary electrophoretic method that covers the concentration range for a full curve clearance estimate of iohexol. In the final method, the plasma samples were protein precipitated and the supernatant was analyzed in a background electrolyte containing borate buffer (0.06 m, pH 10.0). The method developed was proved to be linear (concentration range 18- 2900 mg/L) and had a good precision (e.g. 2.3-2.9% at 88 mg/L) and accuracy (e.g. 101-105% at 88 mg/L). Finally, the method was compared with a previously published and validated HPLC-UV method by parallel analysis of clinical plasma samples from dogs and cats administered Omnipaque®. This comparison showed excellent agreement between the two methods and no proportional or systematic error was observed. The proposed method is simple and has a low cost per sample, which makes it applicable for routine analysis.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium hydroxide, anhydrous, free-flowing, Redi-Dri, reagent grade, ≥98%, pellets
Sigma-Aldrich
Sodium dodecyl sulfate, BioReagent, suitable for electrophoresis, Molecular Biology, ≥98.5% (GC), free-flowing, Redi-Dri
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acrylamide, ≥98.0%
Sigma-Aldrich
Acrylamide, ≥99.9%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Sodium hydroxide solution, 1.0 N, BioReagent, suitable for cell culture
Supelco
Hydrogen chloride – methanol solution, ~1.25 m HCl (T), derivatization grade (GC derivatization), LiChropur
Supelco
Hydrogen chloride – 2-propanol solution, ~1.25 M HCl (T), derivatization grade (GC derivatization), LiChropur
Sigma-Aldrich
Acrylamide, for Northern and Southern blotting, powder blend
Sigma-Aldrich
Sodium hydroxide solution, BioUltra, Molecular Biology, 10 M in H2O
Supelco
Hydrogen chloride – ethanol solution, ~1.25 M HCl, derivatization grade (GC derivatization), LiChropur
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Sodium hydroxide, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Sodium hydroxide solution, 5.0 M
Sigma-Aldrich
Sodium hydroxide, BioUltra, suitable for luminescence, ≥98.0% (T), pellets
Supelco
Sodium hydroxide concentrate, 0.1 M NaOH in water (0.1N), Eluent concentrate for IC
Supelco
Sodium hydroxide solution, 49-51% in water, eluent for IC
Sigma-Aldrich
Sodium hydroxide, beads, 16-60 mesh, reagent grade, 97%
Sigma-Aldrich
Sodium hydroxide, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
Sodium hydroxide, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Sodium hydroxide solution, 50% in H2O
Sigma-Aldrich
Sodium hydroxide, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%