Skip to Content
Merck
CN
  • Determination of internal energy distributions of laser electrospray mass spectrometry using thermometer ions and other biomolecules.

Determination of internal energy distributions of laser electrospray mass spectrometry using thermometer ions and other biomolecules.

Journal of the American Society for Mass Spectrometry (2014-07-12)
Paul M Flanigan, Fengjian Shi, Johnny J Perez, Santosh Karki, Conrad Pfeiffer, Christian Schafmeister, Robert J Levis
ABSTRACT

The internal energy distributions for dried and liquid samples that were vaporized with femtosecond duration laser pulses centered at 800 nm and postionized by electrospray ionization-mass spectrometry (LEMS) were measured and compared with conventional electrospray ionization mass spectrometry (ESI-MS). The internal energies of the mass spectral techniques were determined by plotting the ratio of the intact parent molecular features to all integrated ion intensities of the fragments as a function of collisional energy using benzylpyridinium salts and peptides. Measurements of dried p-substituted benzylpyridinium salts using LEMS resulted in a greater extent of fragmentation in addition to the benzyl cation. The mean relative internal energies, <E(int)> were determined to be 1.62 ± 0.06, 2.0 ± 0.5, and 1.6 ± 0.3 eV for ESI-MS, dried LEMS, and liquid LEMS studies, respectively. Two-photon resonances with the laser pulses likely caused lower survival yields in LEMS analyses of dried samples but not liquid samples. In studies with larger biomolecules, LEMS analyses of dried samples from glass showed a decrease in survival yield compared with conventional ESI-MS for leucine enkephalin and bradykinin of ~15% and 11%, respectively. The survival yields for liquid LEMS analyses were comparable to or better than ESI-MS for benzylpyridinium salts and large biomolecules.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Leucine, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
DL-Leucine, ≥99% (HPLC)
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard