Merck
CN
  • Environmental friendly method for urban wastewater monitoring of micropollutants defined in the Directive 2013/39/EU and Decision 2015/495/EU.

Environmental friendly method for urban wastewater monitoring of micropollutants defined in the Directive 2013/39/EU and Decision 2015/495/EU.

Journal of chromatography. A (2015-10-04)
Ana R Ribeiro, Marta Pedrosa, Nuno F F Moreira, Manuel F R Pereira, Adrián M T Silva
ABSTRACT

The fate and removal of organic micropollutants in the environment is a demanding issue evidenced by the recent European policy. This work presents an analytical method for the trace quantification of 37 micropollutants including Priority Substances (Directive 2013/39/EU), substances of the recent watch list (Decision 2015/495/EU) and contaminants of emerging concern: pesticides, multi-class pharmaceuticals and a metabolite, estrogens and one industrial compound. The analytical method was based on solid phase extraction (SPE) followed by ultra-high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS), using eco-friendly solvents (ethanol and ultrapure water) both in the SPE and UHPLC, according to green analytical chemistry principles. Briefly, Oasis(®) HLB cartridges were used to preconcentrate 100mL of water samples and the reconstituted extracts were analyzed with a Kinetex™ column under reversed mode, the linear ranges extended to 200ngL(-1) (R(2)>0.99) for all the analytes. The method detection limits were between 0.04 and 2.26ngL(-1) and the method quantification limits were between 0.13 and 6.85ngL(-1). The identity of the compounds was confirmed using two MS/MS transitions and its ion ratios, according to Decision 2002/657/EC. The validated method was applied to wastewater treatment plant samples, assessing the concentration of micropollutants after secondary biological and tertiary UV treatments. Lab-scale photolysis and ozonation experiments were also performed with the secondary effluents, with ozonation showing the best performance for the removal of most of the determined micropollutants.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ammonium acetate, Vetec, reagent grade, 97%
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
Carbamazepine, meets USP testing specifications
Sigma-Aldrich
Trimethoprim, ≥98.5%
Sigma-Aldrich
Bezafibrate, ≥98%, solid
Sigma-Aldrich
Ethanol Fixative 80% v/v, suitable for fixing solution (blood films)
Supelco
Ethanol standards 10% (v/v), 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
Diclofenac sodium salt
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Sulfuric acid, 99.999%
Sigma-Aldrich
Trimethoprim, ≥99.0% (HPLC)
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Sulfuric acid, puriss. p.a., for determination of Hg, ACS reagent, reag. ISO, reag. Ph. Eur., 95.0-97.0%
Sigma-Aldrich
Sulfuric acid, ACS reagent, 95.0-98.0%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Sulfuric acid, puriss., meets analytical specification of Ph. Eur., BP, 95-97%
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Ibuprofen, ≥98% (GC)
Sigma-Aldrich
Ibuprofen, meets USP testing specifications
Sigma-Aldrich
Naproxen, meets USP testing specifications
Sigma-Aldrich
Citalopram hydrobromide, ≥98% (HPLC)
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, meets USP testing specifications