Skip to Content
Merck
CN
  • Development of high internal phase emulsion polymeric monoliths for highly efficient enrichment of trace polycyclic aromatic hydrocarbons from large-volume water samples.

Development of high internal phase emulsion polymeric monoliths for highly efficient enrichment of trace polycyclic aromatic hydrocarbons from large-volume water samples.

Journal of chromatography. A (2015-06-17)
Rihui Su, Guihua Ruan, Honggang Nie, Ting Xie, Yanjie Zheng, Fuyou Du, Jianping Li
ABSTRACT

In this work, polymerized high internal phase emulsion (polyHIPE) monoliths were prepared and applied as monolithic adsorbent materials for proconcentration of trace polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples. The monolithic polyHIPE columns were prepared by in situ polymerization of the continuous phase of a high internal phase emulsion (HIPE) containing styrene (STY), divinylbenzene (DVB) and glycidyl methacrylate (GMA) in pipette tips, and the resulting STY/DVB/GMA polyHIPE monoliths exhibited highly interconnected porosity and large surface areas, making them excellent candidates as adsorbents for enrichment of trace aromatic compounds. The prepared STY/DVB/GMA polyHIPE monoliths were applied to the determination of trace PAHs in environmental water samples by combing with high performance liquid chromatography-fluorescence detection (HPLC-FLD). Under the optimized experimental conditions, the polyHIPE monoliths could effectively enrich trace 13 PAHs from 500mL of water samples, the mean recoveries at four spiked levels were ranged from 80.7% to 115.0% with the relative standard deviations (RSDs) lower than 14%, and the detection limits (LODs) were ranged from 4.0 to 228pg/L. In addition, the prepared polyHIPE monolith was stable enough for more than 200 replicate extraction cycles without measurable loss of performance on the enrichment of PAHs, and good column-to-column repeatability was obtained with RSD less than 13%. The proposed method was applied to simultaneous analysis of 13 PAHs in water samples with satisfactory recoveries.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Aniline, ReagentPlus®, 99%
Sigma-Aldrich
Anthracene, ReagentPlus®, 99%
Sigma-Aldrich
Benzo[b]fluoranthene, 98%
Sigma-Aldrich
Pyrene, sublimed grade, 99%
Sigma-Aldrich
Anthracene, sublimed grade, ≥99%
Sigma-Aldrich
Glycidyl methacrylate, ≥97.0% (GC)
Sigma-Aldrich
Aniline, ACS reagent, ≥99.5%
Sigma-Aldrich
Benzaldehyde, ReagentPlus®, ≥99%
Sigma-Aldrich
Benzaldehyde, purified by redistillation, ≥99.5%
Sigma-Aldrich
Glycidyl methacrylate, 97%, contains 100 ppm monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
Pyrene, 98%
Sigma-Aldrich
Divinylbenzene, technical grade, 55%
Sigma-Aldrich
Benzo[k]fluoranthene, suitable for fluorescence, ≥99%
Sigma-Aldrich
Benzaldehyde, ≥98%, FG, FCC
Sigma-Aldrich
Naphthalene, suitable for scintillation, ≥99%
Sigma-Aldrich
Styrene, ReagentPlus®, contains 4-tert-butylcatechol as stabilizer, ≥99%
Sigma-Aldrich
Benzaldehyde, natural, FCC, FG
Sigma-Aldrich
Fluorene, 98%
Sigma-Aldrich
Anthracene, reagent grade, 97%
Sigma-Aldrich
Pyrene, puriss. p.a., suitable for fluorescence, ≥99.0% (GC)
Sigma-Aldrich
Naphthalene, 99%
Sigma-Aldrich
Anthracene, suitable for scintillation, ≥99.0% (GC)
Sigma-Aldrich
Toluene, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Potassium persulfate, 99.99% trace metals basis
Sigma-Aldrich
Fluoranthene, 98%
Sigma-Aldrich
Phenol, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.5-100.5% (GC)
Sigma-Aldrich
Phenol, ACS reagent, ≥99.0%
Sigma-Aldrich
Toluene, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%