Skip to Content
Merck
CN
  • Relationships between Chemical Characteristics and Phytotoxicity of Biochar from Poultry Litter Pyrolysis.

Relationships between Chemical Characteristics and Phytotoxicity of Biochar from Poultry Litter Pyrolysis.

Journal of agricultural and food chemistry (2015-07-08)
Alessandro G Rombolà, Giovanni Marisi, Cristian Torri, Daniele Fabbri, Alessandro Buscaroli, Michele Ghidotti, Andreas Hornung
ABSTRACT

Three biochars were prepared by intermediate pyrolysis from poultry litter at different temperatures (400, 500, and 600 °C with decreasing residence times) and compared with biochars from corn stalk prepared under the same pyrolysis conditions. The phytotoxicity of these biochars was estimated by means of seed germination tests on cress (Lepidium sativum L.) conducted in water suspensions (at 2, 5, and 40 g/L) and on biochars wetted according to their water-holding capacity. Whereas the seeds germinated after 72 h in water suspensions with corn stalk biochar were similar to the control (water only), significant inhibition was observed with poultry litter biochars. In comparison to corn stalk, poultry litter generated biochars with higher contents of ash, ammonium, nitrogen, and volatile fatty acids (VFAs) and a similar concentration of polycyclic aromatic hydrocarbons (PAHs). Results from analytical pyrolysis (Py-GC-MS) indicated that nitrogen-containing organic compounds (NCCs) and aliphatic components were distinctive constituents of the thermally labile fraction of poultry litter biochar. The inhibition of germination due to poultry litter biochar produced at 400 °C (PL400) was suppressed after solvent extraction or treatment with active sludge. A novel method based on solid-phase microextraction (SPME) enabled the identification of mobile organic compounds in PL400 capable of being released in air and water, including VFAs and NCCs. The higher phytotoxicity of poultry litter than corn biochars was tentatively attributed to hydrophilic biodegradable substances derived from lipids or proteins removable by water leaching or microbial treatments.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, pink hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 1, pink hub
Supelco
SPME Fiber Assembly, 7 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, green hub
Supelco
SPME Fiber Assembly, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, white hub
Supelco
SPME Fiber Assembly, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, white hub
Supelco
SPME Portable Field Sampler, coating CAR/PDMS
Supelco
SPME Portable Field Sampler, coating PDMS
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 30 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, yellow hub
Supelco
SPME Fiber Assembly, 30 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, yellow hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, red hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 7 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, green hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 1, red hub
Sigma-Aldrich
Cyclohexane, anhydrous, 99.5%
Sigma-Aldrich
Chrysene-d12, 98 atom % D
Sigma-Aldrich
Nonane, anhydrous, ≥99%
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, red hub
Supelco
SPME Overcoated Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, notched pink hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, red hub
Supelco
SPME Portable Field Sampler, coating PDMS/DVB
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME Fiber Assembly, 60 μm PEG, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 3, purple hub
Supelco
SPME Fiber Assembly, 7 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, green hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, pink hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, red hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, pink hub
Supelco
SPME Sampling Stand, for use with 15 mL vials