Skip to Content
Merck
CN
  • Rapid quick, easy, cheap, effective, rugged, and safe extraction with novel phospholipid cleanup: A streamlined ultra high performance liquid chromatography with ultraviolet detection approach for screening polycyclic aromatic hydrocarbons in avian blood cells and plasma.

Rapid quick, easy, cheap, effective, rugged, and safe extraction with novel phospholipid cleanup: A streamlined ultra high performance liquid chromatography with ultraviolet detection approach for screening polycyclic aromatic hydrocarbons in avian blood cells and plasma.

Journal of separation science (2015-05-28)
Anthony A Provatas, Alexander V Yevdokimov, Cory A King, Emma L Gatley, James D Stuart, David C Evers, Christopher R Perkins
ABSTRACT

A streamlined method has been developed for the isolation and analysis of polycyclic aromatic hydrocarbons in avian blood cells and plasma utilizing quick, easy, cheap, effective, rugged, and safe extraction in combination with novel phospholipid cleanup technology. A variety of traditional extraction and cleanup techniques have been employed in the preparation and analysis of polycyclic aromatic hydrocarbonsin a variety of matrices; liquid-liquid partitioning, solid-phase extractions, gel permeation chromatography, and column chromatography are all effective techniques, however they are laborious and time consuming processes that require large amounts of solvent. Using quick, easy, cheap, effective, rugged, and safe extraction coupled with phospholipid cleanup, samples can be quickly screened while maintaining high throughput and sensitivity. With a liquid chromatography approach, analysis times may be kept short at 16 min while maintaining high analyte recovery. Recoveries in quality control samples ranged from 70 to 109%, with average surrogate recoveries of 80.6 ± 1.10%. The result of using a quick, easy, cheap, effective, rugged, and safe extraction approach in conjunction with phospholipid cleanup is a methodology that significantly reduces sample preparation time and solvent use while maintaining high sensitivity and reproducibility.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Naphthalene-d8, 99 atom % D, ≥98% (CP)
Sigma-Aldrich
Chrysene-d12, 98 atom % D
Sigma-Aldrich
Sodium acetate, anhydrous, BioUltra, suitable for luminescence, Molecular Biology, ≥99.0% (NT)
Sigma-Aldrich
Sodium acetate, powder, BioReagent, suitable for electrophoresis, suitable for cell culture, suitable for insect cell culture, ≥99%
Sigma-Aldrich
Sodium acetate solution, BioUltra, Molecular Biology, ~3 M in H2O
Sigma-Aldrich
Sodium acetate, BioXtra, ≥99.0%
Sigma-Aldrich
Sodium acetate, anhydrous, Molecular Biology, ≥99%
Sigma-Aldrich
Sodium acetate, meets USP testing specifications, anhydrous
Sigma-Aldrich
Sodium acetate, 99.995% trace metals basis
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Perylene-d12, 98 atom % D
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Sodium Acetate Anhydrous, >99%, FG
Sigma-Aldrich
Sodium acetate, Vetec, reagent grade, 98%
Sigma-Aldrich
Acetone, ≥99%, FCC, FG
Sigma-Aldrich
Acetone, natural, ≥97%
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
Magnesium sulfate solution, BioUltra, Molecular Biology
Sigma-Aldrich
Magnesium sulfate solution, Molecular Biology, 1.00 M±0.04 M
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Dichloromethane, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Magnesium sulfate, ≥99.99% trace metals basis
Sigma-Aldrich
Magnesium sulfate, BioReagent, suitable for cell culture, suitable for insect cell culture
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Magnesium sulfate, Vetec, reagent grade
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG