Skip to Content
Merck
CN
  • Optimization of solid-phase microextraction sampling for analysis of volatile compounds emitted from oestrous urine of mares.

Optimization of solid-phase microextraction sampling for analysis of volatile compounds emitted from oestrous urine of mares.

Zeitschrift fur Naturforschung. C, Journal of biosciences (2010-04-02)
Raimondas Mozūraitis, Vincas Būda, Anna-Karin Borg-Karlson
ABSTRACT

The solid-phase microextraction (SPME) technique was applied and optimized for collection of volatile compounds emitted from oestrous urine of mares Equs cabalus L. (Perissodactyla, Equidae) for GC-MS analyses. Variables such as type of SPME fibre, collection time of volatiles, and addition of salt were optimized to improve the sampling efficiency in two aspects: extent and selectivity of absorption/adsorption of urine volatiles onto SPME fibres. The data revealed that the number of volatiles and the total amount represented as quantitative peak areas of the compounds trapped on fibres coated either with polydimethylsiloxane-divinylbenzene or with divinylbenzene-carboxen-polydimethylsiloxane were significantly higher compared to those coated with polydimethylsiloxane, polyacrylate, and carbowax-divinylbenzene. The polydimethylsiloxane-divinylbenzene-type of fibre coating was chosen for optimization of sampling time and effect of salt addition. Sampling periods lasted for 15, 30, 60, 120, and 240 min. The optimal collection time of volatiles from urine maintained at about 36 degrees C was 60 min, as the number of compounds detected with amounts sufficient for quantification did not differ significantly from those trapped during longer collection periods. No significant increase in total amount of volatiles trapped was registered after 120 min of sampling. Addition of 0.3 g NaCl to the 2-ml of samples shortened the collection period from 60 to 15 min during which almost all compounds were trapped. Addition of salt has a significant effect at all sampling periods taking into consideration the total amounts of volatiles trapped. The total intensities increased about 8, 5, 3, 3, and 2 times at collection periods of 15, 30, 60, 120, and 240 min, respectively, when compare with the ones obtained from the urine samples with no salt addition. In oestrous mare's urine, 139 +/- 4 (average number +/- standard deviation) volatile compounds suitable for quantitative analyses were detected compared to 45 compounds collected by the gas-tight syringe method.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, black hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, black hub
Supelco
Carboxen®-1006 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 569, 20-45 mesh, bottle of 10 g
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, Metal Alloy (1cm), needle size 23 ga, Autosampler, pk of, plain gray hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, Metal Alloy (2cm), needle size 23 ga, Autosampler, pk of 1, plain gray hub
Supelco
Carboxen® Adsorbent, matrix Carboxen® 569, 20-45 mesh, bottle of 500 g
Supelco
Carboxen®-1006 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, black hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (1cm), needle size 24 ga, Manual Holder, pk of 3, plain gray hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 24 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, light blue hub
Supelco
Carboxen® 1000 Reversible SPE Tube, 200 mg/mL, pk 30
Supelco
Carboxen® Adsorbent, matrix Carboxen® 564, 20-45 mesh, pack of 144 × 290 mg
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
Carboxen® 572 for Tobacco Smoke, Adsorbent Bed Wt: 300 mg, cartridge size 3 mL, pkg of 50 ea
Supelco
ORBO-93 Sorbent Tube, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 1, light blue hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, black hub
Supelco
ORBO 78 HBr on Carboxen® 564 specially cleaned (20/45), 400/200 mg, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea