跳转至内容
Merck
CN

1.02147

Contact DC

Envirocheck™, Disinfection Control coated with CASO (Tryptic Soy) Agar

选择规格

变更视图

关于此项目

NACRES:
NA.74
UNSPSC Code:
41116116
eCl@ss:
40050204
登录 查看您的价格
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


Quality Segment

material

plastic cap, plastic slide, plastic tube

product line

Envirocheck™

form

solid (ready-to-use)

manufacturer/tradename

Envirocheck™

application(s)

food and beverages
surface monitoring
water monitoring

storage temp.

2-8°C

suitability

bacteria (microbial load - before and after disinfection)

General description

(Disinfection Control) Envirocheck™
Envirocheck Contact Disinfection Control, a semi-quantitative detection of microorganisms on surfaces and in liquids, are flexible paddles that are coated with Tryptic soy agar to check the effectiveness of disinfection. Slide A is coated with CASO (Tryptic Soy) Agar to determine the total viable (aerobic) count and Slide B is coated with CASO (Tryptic Soy) agar containing neutralizers such as Polysorbat 80, Sodium thiosulphate, Lecithin and Histidine. The use of these neutralizers allows growth of bacteria that were held in bacteriostasis after sanitation/disinfection but still viable

Application

Envirocheck contact slides can be used for both surface and liquid testing.

Analysis Note

Count the number of colonies on both sides of the paddle. CASO Agar: count the number of colonies for obtaining the microbial load before disinfection. CASO Agar with neutralizers: count the number of colonies to obtain the microbial load of surviving microorganisms after disinfection. Growth indicates that disinfection was either not adequate (too low concentration of disinfectant) or the effective time was too short.
Microbial contamination: no growth
pH-value/side one (25 °C): 7.0 - 7.6
pH-value/side two (25 °C): 7.0 - 7.6
Growth/side one
- Escherichia coli ATCC 8739 (WDCM 00012):
good
- Staphylococcus aureus ATCC 6538 (WDCM 00032): good
- Candida albicans ATCC 10231 (WDCM 00054): good
- Bacillus subtilis ATCC 6633 (WDCM 00003): good
- Pseudomonas aeruginosa ATCC 9027 (WDCM 00026): good
- Aspergillus brasiliensis (formerly A. niger) ATCC 16404 (WDCM 00053): good
Growth/side two
- Escherichia coli ATCC 8739 (WDCM 00012):
good
- Staphylococcus aureus ATCC 6538 (WDCM 00032): good
- Candida albicans ATCC 10231 (WDCM 00054): good
- Bacillus subtilis ATCC 6633 (WDCM 00003): good
- Pseudomonas aeruginosa ATCC 9027 (WDCM 00026): good
- Aspergillus brasiliensis (formerly A. niger) ATCC 16404 (WDCM 00053): good
Incubation: 48 hrs.; 35 °C; aerobic; Aspergillus up to 72 hrs.

Legal Information

ENVIROCHECK is a trademark of Merck KGaA, Darmstadt, Germany


存储类别

11 - Combustible Solids

WGK

WGK 1



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?