Merck
CN
所有图片(3)

文件

安全信息

MMPPLUVHP

Millipore

Milliflex Oasis® VHP resistant filtration pump with no power supply

The Milliflex Oasis®VHP resistant vacuum pump is suitable for use in isolators. The pump is VaporHydrogen Peroxide (VHP) resistant and compatible, suitable for sterility testing

登录查看公司和协议定价

包装

pkg of 1 unit

manufacturer/tradename

Milliflex Oasis®

technique(s)

Rapid Sterility Testing: suitable

application(s)

bioburden testing
pharmaceutical

sterility testing

相容性

for use with Milliflex Oasis® Systems standard for VHP

运输

ambient

一般描述

The compact Milliflex Oasis® VHP resistant pump streamlines filtration steps during testing to accelerate and ease the sample preparation. When used with convenient Milliflex Oasis® filtration funnels, the pump and Milliflex Oasis® units comprise an integrated solution for delivering reliable and accurate results. The pump′s small footprint suits tight workspaces and its low profile allow easy access and usage in isolators. The housing and the external parts are VHP resistant.

特异性

Frame Stainless steel316 L

Filtration heads Two per pump, Stainless steel, silicone, rubbergasketsNote: The pump head including all its components can be autoclaved at 121 °C for 15 minutes OR at 134 °C for 5 minutes.


Pump dimensions

 Height 90 mm (3.5in.)

Width 230 mm (9.0in.)

Depth 310 mm (12.2in.)

Filtration support height 70 mm (2.8 in.)

Weight with filtration heads 3.4 kg (7.5 lb)

Power supply 100V–240V;50/60Hz — One set can be used for up to two pumps

应用

The Milliflex Oasis® VHP resistant pump is designed to perform filtrations of samples inside an isolator. It is suitable for rapid sterility testing in combination with the Milliflex® Rapid System 2.0.

特点和优势

  • Streamlines filtration steps
  • Compatible with the isolator environment and VHP decontamination
  • Compatible with the Milliflex® Rapid System 2.0 to perform rapid sterility testing in a clean environment (isolator)

其他说明

Easy set-up

  • Quick connections for power and drain tubing
  • No calibration needed
Ergonomics
Low height - 90 mm (3.5 in.)

Cross-contamination prevention
  • Check valve situated in the removable filtration head prevents potential contamination
  • Accessible key parts of the head for easy cleaning
High throughput
Scalability: Connect up to 2 pumps and start up to 4 simultaneous filtrations with a single push of the button

法律信息

MILLIFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIFLEX OASIS is a registered trademark of Merck KGaA, Darmstadt, Germany

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

为方便起见,与您过往购买产品相关的文件已保存在文档库中。

访问文档库

难以找到您所需的产品或批次号码?

在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).

示例

T1503
货号
-
25G
包装规格/数量

其它示例:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

输入内容 1.000309185)

遇到问题?欢迎随时联系我们技术服务 寻求帮助

批号可以在产品标签上"批“ (Lot或Batch)字后面找到。

Aldrich 产品

  • 如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。

  • 如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。

  • 如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。

未找到您寻找的产品?

部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。

索取COA

商品

Use Milliflex® Rapid System to detect cell-based immunotherapeutics for microbial contaminants. This automated ATP-based system supports rapid detection, imaging, and quantification of viable microorganisms.

Milliflex® Rapid System 2.0, an automated solution for rapid microbial detection supports QC labs to substantially reduce the time-to-result of sterility, bioburden, in-process, and product release testing. Thanks to the ATP bioluminescence technology, the system delivers 4 times faster results than traditional methods.

相关内容

The automated Milliflex® Rapid system can get you bioburden testing and sterility testing results days earlier. Its proven technology rapidly and accurately detects microorganisms in sterility, bioburden, in-process and product release testing.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门