推荐产品
形式
powder
质量水平
颜色
white to off-white
mp
181-185 °C (dec.) (lit.)
溶解性
methanol: 1 mg/mL
适用性
suitable for determination of calcium
应用
diagnostic assay manufacturing
hematology
histology
储存温度
room temp
SMILES字符串
Cc1cc(cc(CN(CC(O)=O)CC(O)=O)c1O)C2(OC(=O)c3ccccc23)c4cc(C)c(O)c(CN(CC(O)=O)CC(O)=O)c4
InChI
1S/C32H32N2O12/c1-17-7-21(9-19(29(17)43)11-33(13-25(35)36)14-26(37)38)32(24-6-4-3-5-23(24)31(45)46-32)22-8-18(2)30(44)20(10-22)12-34(15-27(39)40)16-28(41)42/h3-10,43-44H,11-16H2,1-2H3,(H,35,36)(H,37,38)(H,39,40)(H,41,42)
InChI key
IYZPEGVSBUNMBE-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
邻甲酚酞络合酮(o-Cresolphthalein Complexone)是一种pH指示剂和(金属络合指示剂),常用于通过量热法检测血清中的钙含量。
应用
邻甲酚酞络合酮的应用包括,通过Ca2+和邻甲酚酞络合酮在碱性溶液中的反应检测血清样本中的钙含量。
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
Annals of clinical biochemistry, 24 ( Pt 4), 345-351 (1987-07-01)
The reasons for the non-linearity of the standard curve for the calcium-cresolphthalein complexone reaction have been investigated. Calcium forms both 1:1 and 2:1 complexes with cresolphthalein complexone; at low calcium concentrations the 1:1 complex predominates and causes non-linearity. At high
Clinical chemistry, 28(10), 2149-2152 (1982-10-01)
We describe the measurement of total calcium and magnesium in serum with an automated microcomputer-controlled stopped-flow analyzer. The calcium method is based on the cresolphthalein complexone procedure, with 2-amino-3-methyl-1-propanol as the alkalinizing agent. The assay, performed on 60-fold prediluted samples
Clinical chemistry, 27(12), 2025-2028 (1981-12-01)
We describe an automated method for calcium assay, for use with the Cobas-Bio centrifugal analyzer. Calcium is reacted with cresolphthalein complexone and the absorbance of the calcium--dye complex at 575 nm is measured. EDTA is then added to break up
Mayo Clinic proceedings, 80(12), 1655-1657 (2005-12-14)
Severe hypocalcemia may require prompt intervention to avoid life-threatening consequences. We report a case in which a 78-year-old man had a critically low serum calcium level measured with use of standard colorimetric assay after gadodiamide administration during magnetic resonance angiography.
American journal of clinical pathology, 82(2), 182-187 (1984-08-01)
An automated calcium method based on o-cresolphthalein complexone chemistry and designed to be used in conjunction with the Beckman ASTRA systems (Beckman Instruments, Inc., Brea, CA) was evaluated. Day-to-day reproducibility studies yielded coefficients of variation ranging from 1.2 to 3.1%.