H7375
二磷酸组胺 一水合物
Histamine receptor ligand
别名:
2-(4-咪唑)乙胺 二磷酸盐, 4-咪唑乙胺 二磷酸盐 一水合物, 组胺 二磷酸盐 一水合物
产品名称
二磷酸组胺 一水合物,
储存温度
−20°C
SMILES字符串
[H]O[H].OP(O)(O)=O.OP(O)(O)=O.NCCc1c[nH]cn1
InChI
1S/C5H9N3.2H3O4P.H2O/c6-2-1-5-3-7-4-8-5;2*1-5(2,3)4;/h3-4H,1-2,6H2,(H,7,8);2*(H3,1,2,3,4);1H2
InChI key
CNSGLKZGHLZDHQ-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
警示用语:
Danger
危险分类
Acute Tox. 4 Oral - Eye Dam. 1 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3
靶器官
Respiratory system
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
Niels van Heerbeek et al.
Archives of otolaryngology--head & neck surgery, 133(8), 763-766 (2007-08-22)
To determine whether intra-individual changes in eustachian tube (ET) function induced by local application of a histamine phosphate solution can be detected using an improved sonotubometer. The function of the ET was measured with a revised sonotubometer before and after
Min Zhou et al.
Molecular pain, 20, 17448069241258113-17448069241258113 (2024-05-15)
Background: Recent studies have demonstrated that activated microglia were involved in the pathogenesis of central sensitization characterized by cutaneous allodynia in migraine. Activation of microglia is accompanied by increased expression of its receptors and release of inflammatory mediators. Acupuncture and
P Marshik et al.
Chest, 115(1), 194-199 (1999-01-30)
To determine optimal storage conditions for histamine diphosphate (HDP) solutions used for bronchoprovocation. HDP was dissolved in buffered saline solution to concentrations of 0.125 to 16 mg/mL and stored in 3-mL unit dose syringes at different temperatures for varying lengths
Y Larivée et al.
The Journal of otolaryngology, 30(6), 319-323 (2002-01-05)
The objectives of this study were to evaluate the reproducibility of the nasal response to histamine with the acoustic rhinometer and to compare the responses in normal and rhinitic subjects. Our study comprised 10 normal and 10 rhinitic subjects. Each
H S Nelson et al.
The Journal of allergy and clinical immunology, 92(5), 750-756 (1993-11-01)
Five commercially available devices for performing prick skin testing were compared for reproducibility, patient acceptance, occurrence of false-negative skin test results, and size distribution of reactions at the negative control sites. Reproducibility of skin testing with 10 mg/ml histamine base
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持