Sign In to View Organizational & Contract Pricing.
Select a Size
About This Item
Empirical Formula (Hill Notation):
C21H17NaO5S
CAS Number:
Molecular Weight:
404.41
NACRES:
NA.47
PubChem Substance ID:
UNSPSC Code:
12171500
EC Number:
263-654-8
MDL number:
InChI key
GBXGEGUVARLBPB-PLMZOXRSSA-M
InChI
1S/C21H18O5S.Na/c1-13-11-15(7-9-18(13)22)21(16-8-10-19(23)14(2)12-16)17-5-3-4-6-20(17)27(24,25)26;/h3-12,22H,1-2H3,(H,24,25,26);/q;+1/p-1/b21-16-;
SMILES string
[Na+].Cc1cc(ccc1O)\C(=C2/C=CC(=O)C(C)=C2)c3ccccc3S([O-])(=O)=O
grade
indicator grade
form
solid
mp
250 °C (dec.) (lit.)
solubility
H2O: 1 mg/mL
λmax
425 nm
application(s)
diagnostic assay manufacturing
hematology
histology
storage temp.
room temp
Quality Level
Related Categories
Application
Cresol Red has been used for checking the immobilized carbonic anhydrase-catalyzed reactions. It has also been used in the loading buffer for MHC (major histocompatibility complex) class I typing through PCR.
Biochem/physiol Actions
Cresol Red is used as a pH indicator.
Storage Class
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Paula C A Jerónimo et al.
The Analyst, 130(8), 1190-1197 (2005-07-16)
An optical biosensor based on immobilised carbonic anhydrase and its application to the determination of the anti-glaucoma agent acetazolamide by enzyme inhibition measurements, is described. The enzyme and a pH indicator dye, cresol red, were physically immobilised in overlapped sol-gel
K Elamrani et al.
Biochimica et biophysica acta, 727(1), 22-30 (1983-01-05)
The kinetics of H+/OH- diffusion across dimyristoyl phosphatidic acid bilayer membranes was measured by following the absorbance of the pH-sensitive indicator Cresol red (o-cresolsulfonphthalein) entrapped in single lamellar vesicles after rapidly changing the external pH in a stopped-flow apparatus. The
K Schilling et al.
Clinical chemistry, 39(2), 251-256 (1993-02-01)
If buffer/indicator systems are used as optical thermometers in multicuvettes, the temperature resolution is limited by errors of optical measurements produced mainly by variations of pathlength and blank transmittance of the wells. Theoretical and practical approaches show that, in multicuvettes
R Schubert
Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. Serie B, Umwelthygiene, Krankenhaushygiene, Arbeitshygiene, praventive Medizin, 187(3), 266-268 (1989-02-01)
A new medium is described for the isolation of P. aeruginosa organisms which have been damaged by chlorination. This medium utilises the fact that with arginine. P. aeruginosa produces a strongly alkaline reaction resulting in an easily identified colour change
K Horie et al.
Analytical biochemistry, 137(1), 80-87 (1984-02-01)
A highly sensitive quantitative method was developed to detect protons released or taken up upon ligand binding. A small change in pH due to proton release or uptake was detected by measuring the difference in the absorbance of a pH
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service