Merck
CN
All Photos(6)

Documents

Safety Information

KITALYSIS-RCM

Sigma-Aldrich

KitAlysis High-Throughput Medium (5, 6, 7) Ring Closing Metathesis Reaction Screening Kit - Pack of 2

Sign Into View Organizational & Contract Pricing

reaction suitability

core: palladium
reaction type: Buchwald-Hartwig Cross Coupling Reaction
reaction type: Heck Reaction
reaction type: Hiyama Coupling
reaction type: Negishi Coupling
reaction type: Sonogashira Coupling
reaction type: Stille Coupling
reaction type: Suzuki-Miyaura Coupling

storage temp.

2-8°C

Application

Screening kit for ring closing metathesis. Step-by-step user guides and a downloadable experimental excel sheets are provided in the below hyperlinks.

Step-by-Step Guide for Ring Closing Metathesis/Cross Metathesis Reaction Screening Kit

Downloadable experimental excel file

Each kit contains 2 customizable screening sets that include the following components:
  • 6x4 pre-weighed catalysts in glass microvials loaded with stir bars and topped with cap mat.
  • 2 (2 mL) ampules each of of ClPh, PhMe, i-PrOAc, Me-THF, and TFA.
  • 1 KitAlysis 24-well reaction block replacement film.
  • 4 empty substrate stock solution reaction vials with stir bars.
  • 1 internal standard.
Monitor reaction progress via TLC-MS by following this protocol

Best when used with KitAlysis Benchtop Inertion Box and 24-well Reaction Block (sold separately).

Features and Benefits

  • Designed and tested by synthetic chemists.
  • Easily run 24-microscale reaction in parallel.
  • 20 μmol reactions with 1 μmol catalyst (5 mol%), 0.2 M concentration, and optional TFA additive.
  • Customizable and downloadable excel template for quick calculations and easy incorporation into electronic laboratory notebooks.

Legal Information

KitAlysis is a trademark of Sigma-Aldrich Co. LLC

Kit Components Only

Product No.
Description

  • SnapIT Ampule Opener, Regular, for 1-2ml, 5-10ml, 10-15ml ampoules 1 EA

Kit Components Also Available Separately

Product No.
Description
SDS

  • 569747Grubbs Catalyst® M204, Umicore 3 µmolSDS

  • 569755Hoveyda-Grubbs Catalyst® M720, Umicore, 97% 3 µmolSDS

  • 579726Grubbs Catalyst® M102, Umicore, 97% 3 µmolSDS

  • 682365Grubbs Catalyst® M207, Umicore 3 µmolSDS

  • 682373Hoveyda-Grubbs Catalyst® M721, Umicore 3 µmolSDS

  • 729345Hoveyda-Grubbs Catalyst® M722, Umicore 3 µmolSDS

  • 900519Isopropyl acetate, anhydrous, ZerO2®, ≥99.6% 8 mLSDS

  • 9005202-Methyltetrahydrofuran, anhydrous, contains 250 ppm BHT as stabilizer, ZerO2®, ≥99.0% 8 mLSDS

  • 900521Chlorobenzene, anhydrous, ZerO2®, 99.8% 8 mLSDS

  • 900522Toluene, anhydrous, ZerO2®, 99.8% 8 mLSDS

  • Z118850Spinbar® magnetic stirring fleas, red, L 10 mm, diam. 3 mm 1 EASDS

See All (11)

Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Flam. Sol. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 - STOT SE 3

Target Organs

Central nervous system

Supplementary Hazards

Storage Class Code

4.1B - Flammable solid hazardous materials

WGK

WGK 3

Regulatory Information

新产品

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

High-Throughput Experimentation in Catalysis and Materials Science.
Gordillo A, et al.
Ullmann's Encyclopedia of Industrial Chemistry (2014)
Spencer D Dreher et al.
Journal of the American Chemical Society, 130(29), 9257-9259 (2008-06-28)
Microscale parallel experimentation was used to discover three catalyst systems capable of coupling secondary organotrifluoroborates with sterically and electronically demanding aryl chlorides and bromides. The ensuing results represent the first comprehensive study of alkylboron coupling to aryl chlorides and, in
Scientist-Led High-Throughput Experimentation (HTE) and Its Utility in Academia and Industry.
Schmink JR, et al.
Aldrichimica Acta, 46, 71-80 (2013)
Karl D Collins et al.
Nature chemistry, 6(10), 859-871 (2014-09-23)
New organic reactivity has often been discovered by happenstance. Several recent research efforts have attempted to leverage this to discover new reactions. In this Review, we attempt to unify reported approaches to reaction discovery on the basis of the practical

Articles

KitAlysis High-Throughput Screening Kits provide solution to efficiently identify or optimize suitable catalytic reaction conditions. Chemist can rapidly run 24 unique micro scale reactions in parallel with tailored conditions.

Protocols

Catalyst screening, KitAlysis™ High-Throughput Screening Kits, Thin layer chromatography (TLC), parallel analysis, parallel synthesisigh-Throughput Buchwald-Hartwig Amination Reaction Screening Kit, TLC-MS analysis

Related Content

Chemical reaction design and optimization in organic synthesis aims to precisely alter reaction parameters to achieve optimum results in finding pathways to target molecules.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service