Select a Size
About This Item
Quality Segment
material
polypropylene device, polypropylene support, silicone seal
sterility
non-sterile
sterilization compatibility
autoclavable compatible
steam-in-place compatible
product line
Lifegard™
feature
hydrophilic
manufacturer/tradename
Lifegard™
parameter
3.5 bar max. differential pressure (50 psid) at 25 °C, 3.5 bar max. inlet pressure (50 psi) at 25 °C
technique(s)
prefiltration: suitable
L
4 in.
W
2.7 in.
cartridge nominal length
4 in. (10 cm)
device size
4 in.
filter diam.
2.9 in. (7.4 cm)
filtration area
0.19 m2
impurities
≤1.0 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <1.0 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤88 mg/cartridge
matrix
Lifegard™
pore size
2.0 μm nominal pore size, 2.0 μm pore size
code
Code N
General description
Cartridge type: Liquid
Features and Benefits
Packaging
Preparation Note
Analysis Note
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 5 L
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer to Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Still not finding the right product?
Explore all of our products under Lifegard™ 2.0 µm nominal, Cartridge
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.