D005N0E03
Clarigard® Cartridge Filter
nominal pore size 0.5 μm, cartridge nominal length × diam. 2 in. (75.0-78.0 mm) × 2.75 in. (70 mm)
Select a Size
About This Item
Recommended Products
material
polypropylene filter
feature
hydrophilic
manufacturer/tradename
Clarigard®
parameter
4.8 bar max. differential pressure (70 psid) at 20 °C
cartridge nominal length × diam.
2 in. (75.0-78.0 mm) × 2.75 in. (70 mm)
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
gravimetric extractables
≤10 mg
pore size
0.5 μm nominal pore size
0.5 μm pore size
input
sample type liquid
cartridge code
Code N (2-226; O-Ring)
Looking for similar products? Visit Product Comparison Guide
1 of 1
This Item | KN06A10FF1 | K003A05FF1 | K003A05TT1 |
---|---|---|---|
fitting inlet/outlet connection for 19 mm (3/4 in.) sanitary flange | fitting inlet/outlet connection for 19 mm (3/4 in.) sanitary flange | fitting inlet/outlet connection for 19 mm (3/4 in.) sanitary flange | fitting inlet/outlet connection for 38 mm (1 1/2 in.) sanitary flange |
material polypropylene filter, polypropylene support, polypropylene housing, silicone seal | material polypropylene filter, polypropylene housing, polypropylene support, silicone seal | material polypropylene filter, polypropylene housing, polypropylene support, silicone seal | material polypropylene filter, polypropylene housing, polypropylene support, silicone seal |
impurities ≤0.5 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction) | impurities ≤0.5 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction) | impurities ≤0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction) | impurities ≤0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction) |
parameter max. inlet temp. at 25 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 5.5 bar max. inlet pressure (80 psi) at 25 °C, 1.0 bar max. inlet pressure (15 psi) at 80 °C, 80 psig max. inlet pressure | parameter max. inlet temp. at 25 °C, 1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 4.8 bar max. differential pressure (70 psid) at 20 °C, 5.5 bar max. inlet pressure (80 psi) at 25 °C, 80 psig max. inlet pressure | parameter max. inlet temp. at 25 °C, 1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 4.8 bar max. differential pressure (70 psid) at 20 °C, 5.5 bar max. inlet pressure (80 psi) at 23 °C, 80 psig max. inlet pressure | parameter max. inlet temp. at 25 °C, 1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 4.8 bar max. differential pressure (70 psid) at 20 °C, 5.5 bar max. inlet pressure (80 psi) at 23 °C, 80 psig max. inlet pressure |
reg. compliance meets FDA 21 CFR 177-182 (all component materials) | reg. compliance meets FDA 21 CFR 177-182 (all component materials) | reg. compliance meets FDA 21 CFR 177-182 (all component materials) | reg. compliance meets FDA 21 CFR 177-182 (all component materials) |
manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® |
General description
Preparation Note
Analysis Note
Other Notes
- Organism Retention: 99.99% retention
- Mode of Action: Filtration (nominal)
- Application: BioProcessing
- Intended Use: Bioborden reduction
- Instructions for Use: Please refer to the Polygard® and Clarigard® Cartidges user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Regulatory Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service