Skip to Content
Merck
CN

89554

TNT buffer solution

BioUltra, Molecular Biology, pH 8.0

Synonym(s):

TRIS NaCl Tween® 20 buffer solution

Sign In to View Organizational & Contract Pricing.

Select a Size


About This Item

NACRES:
NA.25
UNSPSC Code:
12161700
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

grade

Molecular Biology

product line

BioUltra

form

liquid

impurities

DNases, none detected, RNases, none detected, insoluble matter, passes filter test, phosphatases, none detected, proteases, none detected

pH

8.0±0.2 (25 °C)

cation traces

Al: ≤1 mg/kg, Ba: ≤1 mg/kg, Bi: ≤1 mg/kg, Ca: ≤5 mg/kg, Cd: ≤1 mg/kg, Co: ≤1 mg/kg, Cr: ≤1 mg/kg, Cu: ≤1 mg/kg, Fe: ≤1 mg/kg, K: ≤20 mg/kg, Li: ≤1 mg/kg, Mg: ≤1 mg/kg, Mn: ≤1 mg/kg, Mo: ≤1 mg/kg, Ni: ≤1 mg/kg, Pb: ≤1 mg/kg, Sr: ≤1 mg/kg, Zn: ≤1 mg/kg

λ

neat

UV absorption

λ: 260 nm Amax: 0.04, λ: 280 nm Amax: 0.03

Quality Level

Application

TRIS NaCl Tween 20 (TNT) buffer solution, pH 8.0 may be used in molecular biology as a washing buffer and potentially as an elution buffer for immuno micro sensors.

Legal Information

TWEEN is a registered trademark of Croda International PLC

Storage Class

12 - Non Combustible Liquids

wgk

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

D A Baunoch et al.
BioTechniques, 12(3), 412-417 (1992-03-01)
In this paper we report on the evaluation of several procedures that allow for the repeated use of an antigen-coated, enzyme-linked immunosorbent assay (ELISA) plate for enzyme immunoassay (EIA). We have shown that antigen-coated ELISA plates that were incubated once
Tiegang Xu et al.
Biomedical microdevices, 14(2), 303-311 (2011-11-04)
With high sensitivity and specificity to antigen, immune micro-sensors can be used in rapid detection of pathogenic microbial. This study proposes and develops a method for rapidly regeneration of antibody on a resonant micro-cantilever sensor. A nitrilotriacetic acid (NTA) derivative

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service