Sign In to View Organizational & Contract Pricing.
Select a Size
Change View
About This Item
NACRES:
NA.32
UNSPSC Code:
12352200
column D × L
6.4 mm × 63.0 mm
capacity
2.5 mg total protein loading(35 μL of human plasma, average human protein concentration 70 mg/mL)
storage temp.
2-8°C
Looking for similar products? Visit Product Comparison Guide
General description
The targeted highly abundant proteins are simultaneously removed by the immobilized specific IgYs when crude biological samples are passed through the column. Selective immunodepletion provides an enriched pool of low abundance proteins for downstream proteomic analyses. Specific removal of these 14 highly abundant proteins depletes ~95% of the total protein mass from human serum or plasma. The low abundance proteins in the flow-through fractions can then be studied. Removal of highly abundant proteins enables improved resolution and dynamic range for one dimensional electrophoresis (1DGE), two-dimensional (2DGE) electrophoresis and liquid chromatography/ mass spectrometry (LC/MS). The collected flow-through fractions may need to be concentrated dependent upon the downstream application.
Seppro™ IgY14 columns allow users to separate 14 highly abundant proteins (HAP) from plasma protein mixtures. The Avian polyclonal IgY (Immunoglobulin Yolk) antibodies, have a distinct, highly specific partitioning advantage over competing products, allowing the researcher to look at a much cleaner human protein mixture. Seppro™ columns make further proteomics analysis into the plasma proteome much easier and provide cleaner results.
Proteins Depleted:
Albumin
IgG
α1-Antitrypsin
IgA
IgM
Transferrin
Haptoglobin
α2-Macroglobulin
Fibrinogen
Complement C3
α1-Acid Glycoprotein (Orosomucoid)
HDL (Apolipoproteins A-I and A-II)
LDL (mainly Apolipoprotein B)
Proteins Depleted:
Albumin
IgG
α1-Antitrypsin
IgA
IgM
Transferrin
Haptoglobin
α2-Macroglobulin
Fibrinogen
Complement C3
α1-Acid Glycoprotein (Orosomucoid)
HDL (Apolipoproteins A-I and A-II)
LDL (mainly Apolipoprotein B)
Application
Seppro™ IgY14, LC2 (2 mL bed volume columns) is designed for use as a plasma/serum protein removal tool base upon immune affinity removal of 14 highly abundant proteins (HAP) from human plasma protein mixtures via liquid chromatography. Seppro™ IgY14 is used to support the analysis of low abundance human serum/plasma proteins.
Preparation Note
Store the column at 2–8 °C. After use, equilibrate the column with 1´ Dilution Buffer containing 0.02% sodium azide and store the column at 2–8 °C with the end-caps tightly sealed. Do Not Freeze the column.
Other Notes
If the protein concentration of the sample is unknown and the total serum protein level is potentially elevated, a reduction of the serum load to 24.0 ml is recommended for initial study to avoid potential abundant protein bleed through.
Legal Information
Seppro is a trademark of Merck KGaA, Darmstadt, Germany
Storage Class
10 - Combustible liquids
Regulatory Information
常规特殊物品
This item has
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Effect of plasma protein depletion on BNP-32 recovery.
Adam M Hawkridge et al.
Clinical chemistry, 54(5), 933-934 (2008-04-30)
Does plasma protein depletion increase lung liquid conductance?
P Dodek
American journal of respiratory and critical care medicine, 154(4 Pt 1), 1213-1215 (1996-10-01)
Renato Millioni et al.
PloS one, 6(5), e19603-e19603 (2011-05-17)
To date, the complexity of the plasma proteome exceeds the analytical capacity of conventional approaches to isolate lower abundance proteins that may prove to be informative biomarkers. Only complex multistep separation strategies have been able to detect a substantial number
Related Content
Instructions
Global Trade Item Number
| SKU | GTIN |
|---|---|
| SEP020-1KT | 04061837017995 |
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service