About This Item
UNSPSC Code:
41115609
manufacturer/tradename
Hanna
TDS measuring range
0.00-10.00 ppt
conductivity
0-20,000 μS/cm (high range)
General description
The waterproof (they even float!) DiST5 and DiST6 testers have a dual-level LCD that displays EC or TDS and °C or °F. These new EC/TDS/Temperature meters have a stainless steel temperature probe for faster and more precise temperature measurement. EC/TDS conversion factor and temperature coefficient factor (β) are user adjustable for application specific measurements.
These advanced EC/TDS/°C/°F meters feature graphite electrodes which provide the greatest possible accuracy since they cannot be contaminated by salt deposits in the solution and when the electrode is finally exhausted simply insert a new electrode cartridge.
The new waterproof (they even float!) DiST5 and DiST6 testers have a dual-level LCD that displays EC or TDS and °C or °F. At startup, DiST performs a self check then displays the remaining battery level to assure proper working condition. These testers also feature a stability indicator and hold feature to prompt the user when to take the reading & freeze the display for easy and accurate recording. These new EC / TDS / Temperature meters have a stainless steel temperature probe for faster and more precise temperature measurement. Calibration and temperature compensation is automatic, while the EC / TDS conversion factor and temperature coefficient factor (β) are user adjustable for application specific measurements.
These advanced EC / TDS / °C / °F meters feature graphite electrodes which provide the greatest possible accuracy since they cannot be contaminated by salt deposits in the solution and when the electrode is finally exhausted simply insert a new electrode cartridge!
Choose your DiST according to the proper EC / TDS ranges for your application:
Specifications:DiST 5 (HI 98311)DiST6 (HI 98312)
Range
EC0 to 3999 μS/cm0.00 to 20.00 mS/cm
TDS0 to 2000 ppm0.00 to 10.00 ppt
Temperature0.0 to 60.0°C or 32.0 to 140.0°F
Resolution:
EC1 μS/cm0.01 mS/cm
TDS1 ppm0.01 ppt
Temperature0.1°C or 0.1°F
Accuracy: (@ 20°C/68°F)
EC±2% Full Scale
TDS±2% Full Scale
Temperature±0.5°C or ±1°F
Typical EMC Deviation:
EC±2% Full Scale
TDS±2% Full Scale
Temperature±1°C or ±2°F
EC / TDS CalibrationAutomatic 1 point at 1413 μS/cmAutomatic 1 point at 1288 mS/cm
EC / TDS Conversion FactorAdjustable from 0.45 to 1.00
Temperature CompensationBETA (β) = adjustable from 0.0 to 2.4 per °C in increments of 0.1
Environment:0 to 50°C (32 to 122°F); R.H. 100%
Battery Type / Life4 × 1.5 V / 100 hours
Auto Shut-offAfter 8 minutes
Dimensions:163 × 40 × 26 mm (6.4 × 1.6 × 1.0")
Weight85 g (3 oz.)
These advanced EC/TDS/°C/°F meters feature graphite electrodes which provide the greatest possible accuracy since they cannot be contaminated by salt deposits in the solution and when the electrode is finally exhausted simply insert a new electrode cartridge.
- Stability indicator
- Freeze display
- Auto calibration and temperature compensation
- Dual Level Display
- Battery Level Indicator
- Replaceable Graphite Electrode
- Rugged, Floating Waterproof Casing
- Temperature in °C and °F
- Automatic Temperature Compensation (ATC)
- Adjustable Temperature Coefficient Factor
The new waterproof (they even float!) DiST5 and DiST6 testers have a dual-level LCD that displays EC or TDS and °C or °F. At startup, DiST performs a self check then displays the remaining battery level to assure proper working condition. These testers also feature a stability indicator and hold feature to prompt the user when to take the reading & freeze the display for easy and accurate recording. These new EC / TDS / Temperature meters have a stainless steel temperature probe for faster and more precise temperature measurement. Calibration and temperature compensation is automatic, while the EC / TDS conversion factor and temperature coefficient factor (β) are user adjustable for application specific measurements.
These advanced EC / TDS / °C / °F meters feature graphite electrodes which provide the greatest possible accuracy since they cannot be contaminated by salt deposits in the solution and when the electrode is finally exhausted simply insert a new electrode cartridge!
Choose your DiST according to the proper EC / TDS ranges for your application:
- DiST5 (HI 98311); EC - 0 to 3999 μS/cm; TDS - 0 to 2000 ppm
- DiST6 (HI 98312); EC - 0.00 to 20.00 mS/cm; TDS - 0.00 to 10.00 ppt
- DiST is supplied complete with EC/TDS Probe (HI 73311), 4 × 1.5V batteries and electrode replacement tool (HI 73128)
Specifications:DiST 5 (HI 98311)DiST6 (HI 98312)
Range
EC0 to 3999 μS/cm0.00 to 20.00 mS/cm
TDS0 to 2000 ppm0.00 to 10.00 ppt
Temperature0.0 to 60.0°C or 32.0 to 140.0°F
Resolution:
EC1 μS/cm0.01 mS/cm
TDS1 ppm0.01 ppt
Temperature0.1°C or 0.1°F
Accuracy: (@ 20°C/68°F)
EC±2% Full Scale
TDS±2% Full Scale
Temperature±0.5°C or ±1°F
Typical EMC Deviation:
EC±2% Full Scale
TDS±2% Full Scale
Temperature±1°C or ±2°F
EC / TDS CalibrationAutomatic 1 point at 1413 μS/cmAutomatic 1 point at 1288 mS/cm
EC / TDS Conversion FactorAdjustable from 0.45 to 1.00
Temperature CompensationBETA (β) = adjustable from 0.0 to 2.4 per °C in increments of 0.1
Environment:0 to 50°C (32 to 122°F); R.H. 100%
Battery Type / Life4 × 1.5 V / 100 hours
Auto Shut-offAfter 8 minutes
Dimensions:163 × 40 × 26 mm (6.4 × 1.6 × 1.0")
Weight85 g (3 oz.)
Legal Information
DiST is a registered trademark of Hanna Instruments
Regulatory Information
新产品
This item has
Choose from one of the most recent versions:
Already Own This Product?