About This Item
Agency
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
Quality Level
vapor density
1.41 (vs air)
vapor pressure
72.8 mmHg ( 20 °C)
Assay
≥99.9% (GC)
form
liquid
autoignition temp.
973 °F
expl. lim.
16 %
refractive index
n20/D 1.344 (lit.)
bp
81-82 °C (lit.)
mp
−45 °C (lit.)
density
0.786 g/mL at 25 °C (lit.)
suitability
suitable for UHPLC-MS
application(s)
PFAS testing
SMILES string
CC#N
InChI
1S/C2H3N/c1-2-3/h1H3
InChI key
WEVYAHXRMPXWCK-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Related Categories
General description
Testing for PFAS requires solvents, such as water, acetonitrile, and methanol of exceptionally high purity, which are utilized in both analytical and preparative stages of the analysis. The high sensitivity of liquid chromatography-mass spectrometry (LC-MS) instruments, combined with the need for trace-level detection of PFAS, necessitates the use of solvents that are free from PFAS contamination. Any presence of PFAS in these solvents can lead to misleading results, resulting in false positives or an overestimation of PFAS levels, ultimately compromising the validity of analytical results and conclusions. Therefore, ensuring solvent purity is paramount for accurate and reliable PFAS analysis. LiChrosolv® solvents, tested for PFAS methods, are engineered to meet the demands of this critical application. Each batch undergoes rigorous testing against all analytes outlined in EPA methods EPA 533, EPA 537.1, and EPA 1633. These solvents are designed to minimize background interference and contain no PFAS compounds above the limit values defined by each EPA method. This ensures reliable and effective testing, facilitating the identification and quantitation of PFAS analytes while eliminating the risk of false positive or negative results in LC-MS/MS analysis.
Application
- QC Batch Tested: 40 PFAS analytes tested according to EPA 533 (25 analytes), EPA 537.1 (18 analytes), and EPA 1633 (40 analytes).
- Lot to Lot Consistency: Multiple batches validated by a third-party accredited testing laboratory and internal laboratories.
Features and Benefits
- Application Security: Quality control on 40 PFAS analytes according to EPA 533, EPA 537.1, and EPA 1633.
- Time and Cost Savings: EPA 1633 requires batch validation unless the vendor tests for PFAS analytes listed in this method.
- Lowest Impurity Profile: Ensures an interference-free baseline.
- LC-MS Suitability: ESI/APCI (+) < 2 ppb; ESI/APCI (-) < 10 ppb.
- Minimized Contamination: Borosilicate glass bottles reduce contamination with metal ions.
- Trace Metal Impurity Control: Levels of trace metal impurities are minimized to <5 ppb, reducing metal ion adduct formation.
- Microfiltration: Solvents are filtered through a 0.2 μm filter to ensure purity.
Legal Information
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point(F)
35.6 °F - closed cup
Flash Point(C)
2.0 °C - closed cup
Choose from one of the most recent versions:
Certificates of Analysis (COA)
Don't see the Right Version?
If you require a particular version, you can look up a specific certificate by the Lot or Batch number.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service