Skip to Content
Merck
CN

12085-U

Metal Packed GC Column (General Configuration)

phase none, matrix 80/100 HayeSep R support, L × O.D. × I.D. 3.0 ft (0.91 m) × 1/16 in. × 1.25 mm, Preconditioned

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View

About This Item

UNSPSC Code:
41115710
NACRES:
SB.54
eCl@ss:
32119290
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


material

stainless steel column

parameter

0-250 °C temperature (isothermal or programmed)

technique(s)

gas chromatography (GC): suitable

L × O.D. × I.D.

3.0 ft (0.91 m) × 1/16 in. × 1.25 mm, Preconditioned

matrix

80/100 HayeSep R support

matrix active group

none phase

column type

packed GC

compatibility

for use with General Configuration

General description

Packed column made up of stainless steel are basically employed when higher carrier gas flow rates are employed as they can sustain elevated pressure. Stainless steel columns are usually washed with dilute hydrochloric acid, then with water followed by methanol, acetone, methylene dichloride and n-hexane in order to remove any corrosion products and traces of lubricating agents. HayeSep R is suitable as the column packing material to act as a protective coating for the stationary phase.
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.

Application

HayeSep R was used for packed column GC for quantitation of methanol, ethanol, isopropanol, acetone and ethylene glycol. It was also used in studies investigating plasma stabilization of pre-mixed methane-air combustion using a miniaturized glide-arc reactor integrated into a Bunsen type burner for plasma-activation of fuel-steam mixtures.

Other Notes

This is a micropacked column. It is packed full and contains stainless steel screens.

This column is preconditioned.


Still not finding the right product?


Storage Class

10 - Combustible liquids

wgk

WGK 2

flash_point_f

Not applicable

flash_point_c

Not applicable

Regulatory Information

新产品

This item has



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Glide-arc stabilization of lean methane-air combustion.
Proc. Int. Symp., 41 (2), 300-305 (1995)
J F Livesey et al.
Clinical chemistry, 41(2), 300-305 (1995-02-01)
We developed a packed-column chromatographic procedure capable of simultaneous quantitation of methanol, ethanol, isopropanol, acetone, and ethylene glycol. This method was then updated to a rapid, sensitive, wide-bore capillary method. The packed-column system uses direct injection of 1 microL of
Introduction to Analytical Gas Chromatography.
Scott RPW.