35483
Florisil® TLC
suitable for thin layer chromatography (TLC)
Synonym(s):
Florisil®, Activated magnesium silicate, Magnesium silicate
Sign Into View Organizational & Contract Pricing
Select a Size
About This Item
Empirical Formula (Hill Notation):
MgO3Si
CAS Number:
Molecular Weight:
100.39
EC Number:
MDL number:
UNSPSC Code:
23201100
PubChem Substance ID:
technique(s)
LPLC: suitable
thin layer chromatography (TLC): suitable
SMILES string
[Mg++].[O-][Si]([O-])=O
InChI
1S/Mg.O3Si/c;1-4(2)3/q+2;-2
InChI key
FKHIFSZMMVMEQY-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
General description
Florisil, adsorbent for the separation of lipids is a commercially-prepared magnesia silica gel. It has a coarse mesh size which helps in rapid flow rate. Florisil is effective in promoting [1,3]-sigmatropic shift of myceophenolic acid related allyl phenyl ethers. Florisil cartridges are used in atmospheric sampling to assess possible interference from air contaminants.
Application
Florisil® TLC was used in TLC separations of organic compounds.
Legal Information
Florisil is a registered trademark of U.S. Silica Company
Storage Class Code
13 - Non Combustible Solids
WGK
nwg
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
dust mask type N95 (US), Eyeshields, Gloves
Regulatory Information
新产品
This item has
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Retention behaviour of model solutes on mixed silica-magnesia adsorbents by TLC. Comparison with the adsorption properties of Florisil.
Waksmundzka-Hajnos,
Chromatographia, 43, 405-412 (1996)
The Florisil? catalyzed [1, 3]-sigmatropic shift of allyl phenyl ethers-An entryway into novel mycophenolic acid analogues.
Talamas, Francisco X., et al.
Tetrahedron Letters, 38, 4725-4728 (1997)
P A de Paula Pereira et al.
Talanta, 49(2), 245-252 (2008-10-31)
A new sampling protocol was developed to determine methanol and ethanol in the gas phase, at low concentration levels, in urban atmospheres. The procedure involves collection of air samples (20.0-30.0 l) with three florisil cartridges connected in series, at a
Stephen T Kelly et al.
Nanotechnology, 20(20), 204017-204017 (2009-05-08)
Despite the promising thermodynamics and storage capacities of many destabilized metal hydride hydrogen storage material systems, they are often kinetically limited from achieving practical and reversible behavior. Such is the case with the Mg2Si system. We investigated the kinetic mechanisms
Lei Zhang et al.
Water science and technology : a journal of the International Association on Water Pollution Research, 63(10), 2114-2122 (2011-10-08)
Florisil was employed for the sorption of antimony ions from aqueous solutions. A detailed study of the process was performed by varying the sorption time, pH, and temperature. The sorption was found to be fast, equilibrium was reached within 15
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service