40250-U

2-Methylphenol solution

certified reference material, 5000 μg/mL in methanol

Synonym(s):

o-Cresol solution, 2-Methylphenol

Sign In to View Organizational & Contract Pricing.

Select a Size


About This Item

CAS Number:
UNSPSC Code:
77101502
NACRES:
NA.24
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

InChI

1S/C7H8O/c1-6-4-2-3-5-7(6)8/h2-5,8H,1H3

InChI key

QWVGKYWNOKOFNN-UHFFFAOYSA-N

grade

certified reference material, TraceCERT®

agency

EPA TO-8, NIOSH 2001

product line

TraceCERT®

feature

standard type calibration

packaging

ampule of 1 mL

concentration

5000 μg/mL in methanol

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

application(s)

environmental

format

single component solution

storage temp.

2-8°C

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

target_organs

Eyes,Central nervous system

Storage Class

3 - Flammable liquids

wgk

WGK 2

flash_point_f

49.5 °F - closed cup

flash_point_c

9.7 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter

Regulatory Information

危险化学品
This item has

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Cristina Quintelas et al.
Biodegradation, 21(3), 379-392 (2009-11-03)
The performance of a biofilm of Arthrobacter viscosus supported on granular activated carbon on the retention of organic compounds was evaluated. The presence of functional groups on the cell wall surface of the biomass that may interact with the organic
P Ducos et al.
International archives of occupational and environmental health, 81(3), 273-284 (2007-07-03)
Biomonitoring of solvents using the unchanged substance in urine as exposure indicator is still relatively scarce due to some discrepancies between the results reported in the literature. Based on the assessment of toluene exposure, the aim of this work was
Young Ku et al.
Environmental technology, 31(2), 139-144 (2010-04-16)
Steady-state dissolved ozone concentrations were maintained relatively constant for experiments on ozone dissolution conducted in the presence of various amounts of sodium dodecyl sulphate (SDS) and Triton X-100 (TX-100), an anionic surfactant and a nonionic surfactant, respectively. Ozonation in a
Hua-Wei Chen et al.
Water research, 41(10), 2069-2078 (2007-04-10)
Platinum deposited TiO(2) films were prepared on quartz substrates by dip-coating process for the photodecomposition of o-cresol. The characteristics of Pt/TiO(2) and the temporal behavior of o-cresol decomposition by Pt/TiO(2) photocatalysis under visible light irradiation were investigated. Platinum deposited on
Osamu Inoue et al.
Industrial health, 46(4), 318-325 (2008-08-22)
This study was initiated to evaluate o-cresol and benzylmercapturic acid in urine in comparison with other biomarkers, as tools to estimate the intensity of occupational exposure to toluene at low levels. In total, 108 solvent exposed workers (engaged in tape

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service