G1007232
LC/MS Analysis of Organophosphonate Nerve Agent Metabolites on SeQuant® ZIC-HILIC
application for LC-MS
technique(s)
LC/MS: suitable
test parameters
column: SeQuant ZIC-HILIC, PEEK, 150 x 2.1 mm, 5 μm, 200 Å (1.50454.0001)
mobile phase: [A] acetonitrile; [B] ammonium acetate; (80:20, A:B)
flow rate: 0.35 mL/min
detector: ESI-MS in negative ion mode (TIC from SIM m/z: 179 (+ fragment 109, 123, 137, 151, 191, 247 and 286) )
injection: 2 μL samples diluted in 70:30 acetonitrile/water