Sign In to View Organizational & Contract Pricing.
Select a Size
Change View
About This Item
Empirical Formula (Hill Notation):
Cl2Pd
CAS Number:
Molecular Weight:
177.33
EC Number:
231-596-2
PubChem Substance ID:
MDL number:
grade
puriss.
Quality Level
concentration
60.0%
mp
678-680 °C (lit.)
density
4 g/mL at 25 °C (lit.)
SMILES string
Cl[Pd]Cl
InChI
1S/2ClH.Pd/h2*1H;/q;;+2/p-2
InChI key
PIBWKRNGBLPSSY-UHFFFAOYSA-L
Looking for similar products? Visit Product Comparison Guide
Application
Application Guide for Palladium Catalyzed Cross-Coupling Reactions
Used in the synthesis of semiconducting metal-containing polymers in which the polypyrrole backbone has a conformational energy minimum and is nearly planar.
Used in the synthesis of semiconducting metal-containing polymers in which the polypyrrole backbone has a conformational energy minimum and is nearly planar.
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Met. Corr. 1 - Skin Sens. 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Storage Class
13 - Non Combustible Solids
Regulatory Information
新产品
This item has
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Guilue Guo et al.
Chemistry, an Asian journal, 9(9), 2555-2559 (2014-06-26)
The coupling of proteins with self-assembly properties and proteins that are capable of recognizing and mineralizing specific inorganic species is a promising strategy for the synthesis of nanoscale materials with controllable morphology and functionality. Herein, GPG-AG3 protein fibers with both
E Sutter et al.
Nature communications, 5, 4946-4946 (2014-09-12)
Galvanic replacement reactions provide an elegant way of transforming solid nanoparticles into complex hollow morphologies. Conventionally, galvanic replacement is studied by stopping the reaction at different stages and characterizing the products ex situ. In situ observations by liquid-cell electron microscopy
A M Lacerda et al.
Nanoscale, 7(29), 12331-12335 (2015-07-08)
A photocatalyst consisting of nanostructured Pd photochemically deposited on 20 nm TiO2 displays a reaction half-life for rhodamine b decolourisation of 0.5 minute compared to the 9.4 minutes for unmodified P25 under identical reaction conditions. We associate this increased decolourisation
Sanki Asakawa et al.
PloS one, 10(3), e0119428-e0119428 (2015-03-06)
Nickel (Ni) ions easily elute from many alloys and elicit inflammation and allergies. Previous studies have shown that infections due to the implantation of medical devices cause inflammation and enhance the elution of Ni ions (Ni²⁺). However, cross-talk between infection-
I Spoerri et al.
Allergy, 70(3), 323-327 (2014-12-03)
We established a flow cytometric lymphocyte proliferation test (LPT) for the detection of nickel (Ni) and palladium (Pd) sensitization. Eighty-one consecutive patients with an indication for patch test (PT) were tested by LPT with Ni (NiSO4 ) and Pd (Na2
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service

