Skip to Content
Merck
CN
  • Quantitative analysis of closantel and rafoxanide in bovine and ovine muscles by high-performance liquid chromatography with fluorescence detection.

Quantitative analysis of closantel and rafoxanide in bovine and ovine muscles by high-performance liquid chromatography with fluorescence detection.

Journal of AOAC International (2010-12-15)
Hoi-Sze Yeung, Wing-Hong Ching, Shirley Sau-Ling Lai, Wai-On Lee, Yiu-Tung Wong
ABSTRACT

An HPLC method with a fluorescence detector (HPLC-FLD) was described for the quantitative determination of closantel and rafoxanide in bovine and ovine muscles. A structural analog closely related to rafoxanide, viz., N-[4-(4-chlorophenoxy)phenyl]-2-hydroxy-3,5-diiodobenzamide, was synthesized as an internal standard. Bovine and ovine muscles were extracted with acetonitrile-acetone (60 + 40, v/v) followed by cleanup on mixed mode anionic exchange SPE cartridges. After evaporation and reconstitution with the mobile phase, the sample was analyzed by HPLC-FLD using internal standard calibration. The method was validated by using fortified bovine and ovine muscles at 15, 30, and 60 microg/kg. The accuracy and RSD were 70-110% and < or =10%, respectively.

MATERIALS
Product Number
Brand
Product Description

Supelco
Closantel, PESTANAL®, analytical standard
Supelco
Rafoxanide, PESTANAL®, analytical standard