Skip to Content
Merck
CN
  • Interpreting hydrodynamic behaviour by the model of stirred tanks in series with exchanged zones: preliminary study in lab-scale trickling filters.

Interpreting hydrodynamic behaviour by the model of stirred tanks in series with exchanged zones: preliminary study in lab-scale trickling filters.

Environmental technology (2014-02-18)
Ming Zeng, Audrey Soric, Jean-Henry Ferrasse, Nicolas Roche
ABSTRACT

In trickling filters for wastewater treatment, hydrodynamic behaviour is affected by the growth of biofilm on the porous medium. Therefore, modelling hydrodynamic behaviour is necessary and efficient to predict the biodegradation of pollutants. In this study, laboratory-scale trickling filters were filled with two different porous media (glass beads and plastic rings) and were fed by a synthetic substrate in batch mode. Total organic carbon (TOC) of the effluent was measured and retention time distribution (RTD) was determined by injecting NaCl. Results showed that medium had no significant effect on TOC removal rate (around 80% and 60% respectively for batch time of seven and two days). However, regarding the hydrodynamic behaviour, the effective volume ratio and hydraulic efficiency in the glass beads bed increased remarkably from 28% and 18% to 80% and 70%, respectively, with the reduction of dispersion coefficient (from 4.55 to 1.53). Moreover, the short batch time accelerated this change. Conversely, no variation of hydrodynamic behaviour in plastic rings bed was evident. Along with the feeding of synthetic substrate, biofilm concentration ranged from 1.5 to 10.1 g/L in the glass beads reactor and it achieved around 2.8 g/L in the plastic rings reactor. Hydrodynamic modelling indicated that the model of stirred tanks in series with exchanged zones fitted the experimental results well. These gave values of mobile and immobile volumes of 51 mL and 17 mL, respectively, in the glass beads filter and 25 mL and 15 mL, respectively, in the plastic rings filter.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Activated Charcoal Norit®, Norit® SX ultra, from peat, steam activated and acid washed, highly purified, powder
Sigma-Aldrich
Activated Charcoal Norit®, Norit® PK 1-3, from peat, steam activated, granular
Sigma-Aldrich
Activated Charcoal Norit®, Norit® SX2, powder, from peat, multi-purpose activated charcoal, steam activated and acid washed
Sigma-Aldrich
Activated Charcoal Norit®, Norit® GAC 1240W, from coal, steam activated, granular
Sigma-Aldrich
Activated Charcoal Norit®, Norit® RB3, steam activated, rod
Sigma-Aldrich
Carbon, nanopowder, <100 nm particle size (TEM)
Sigma-Aldrich
Carbon, glassy, spherical powder, 2-12 μm, 99.95% trace metals basis
Sigma-Aldrich
Activated charcoal, suitable for cell culture, suitable for plant cell culture
Sigma-Aldrich
Activated charcoal, DARCO®, 12-20 mesh, granular
Sigma-Aldrich
Activated Charcoal, meets USP testing specifications
Millipore
Activated charcoal, suitable for GC
Supelco
Activated Charcoal Norit®, Norit® RBAA-3, rod
Sigma-Aldrich
Activated charcoal, untreated, granular, 20-60 mesh
Supelco
Activated charcoal, puriss. p.a., powder
Sigma-Aldrich
Activated charcoal, DARCO®, 4-12 mesh particle size, granular
Sigma-Aldrich
Activated charcoal, DARCO®, 20-40 mesh particle size, granular
Sigma-Aldrich
Activated charcoal, powder, -100 particle size (mesh), decolorizing
Sigma-Aldrich
Activated charcoal, acid-washed with hydrochloric acid
Sigma-Aldrich
Activated charcoal, untreated, granular, ≤5 mm
Supelco
Activated charcoal, powder
Supelco
Activated charcoal, for the determination of AOX, 50-150 μm particle size
Sigma-Aldrich
Activated charcoal, Norit® ROW 0.8 SUPRA, pellets
Sigma-Aldrich
Activated charcoal, acid-washed with phosphoric and sulfuric acids
Sigma-Aldrich
Activated charcoal, DARCO®, −100 mesh particle size, powder