Skip to Content
Merck
CN
  • Assessment of the complementarity of temperature and flow-rate for response normalisation of aerosol-based detectors.

Assessment of the complementarity of temperature and flow-rate for response normalisation of aerosol-based detectors.

Journal of chromatography. A (2014-07-09)
Manish M Khandagale, Emily F Hilder, Robert A Shellie, Paul R Haddad
ABSTRACT

The solvent dependency of the detection response is a major limitation of corona-charged aerosol detection (C-CAD). The present study empirically investigates the utility of temperature and flow-rate gradients to overcome solvent gradient limitations of C-CAD. In preliminary flow-injection investigations, it is demonstrated that the response of C-CAD remains relatively unaltered with variations in flow-rate when used with water-rich eluents. Based on these findings two separation approaches were developed and their utility for C-CAD response normalisation was demonstrated using a mixture of eight analytes. In the first approach the use of a solvent gradient is replaced with a temperature gradient performed under isocratic mobile phase conditions. Detection response is further enhanced by mixing a secondary stream of pure acetonitrile with the column effluent, yielding a 3-fold increase in detection response. In the second approach, flow-rate programming is used to improve speed of isocratic-temperature gradient separation. The use of simultaneous variation in flow-rate and column temperature reduced the separation time by 30%, with relatively uniform analyte response. Lastly, an inverse-gradient solvent compensation approach was used to evaluate the response homogeneity and the applicability of the above approaches for quantitative analysis. Good peak area reproducibility (RSD%<15%) and linearity (R(2)>0.994, on a log-scale) over the sample mass range of 0.1-10 μg was achieved. The response deviation across the mixture of eight compounds at seven concentration levels was 6-13% compared to 21-39% when a conventional solvent gradient was applied and this response deviation was comparable to that obtained in the inverse gradient solvent compensation approach. Finally, applicability of these approaches for typical pharmaceutical impurity profiling was demonstrated at a concentration of 5 μg/mL (0.1% of the principal compound).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Ammonium acetate solution, Molecular Biology, 7.5 M
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetic acid, suitable for luminescence, BioUltra, ≥99.5% (GC)
Supelco
Acetic acid, analytical standard
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetic acid, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
Acetic acid, glacial, puriss., 99-100%
Sigma-Aldrich
Acetic acid, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetic acid solution, suitable for HPLC
Sigma-Aldrich
Acetic acid, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Ammonium acetate, BioUltra, ≥99.0%
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Supelco
Ammonium acetate, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Ammonium acetate, Molecular Biology, ≥98%
Sigma-Aldrich
Ammonium acetate solution, BioUltra, ~5 M in H2O
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%