Skip to Content
Merck
CN
  • Potential analytical interferences and seasonal variability in diethyltoluamide environmental monitoring programs.

Potential analytical interferences and seasonal variability in diethyltoluamide environmental monitoring programs.

Chemosphere (2015-03-10)
Sylvain Merel, Andrey I Nikiforov, Shane A Snyder
ABSTRACT

N,N-diethyl-m-toluamide (DEET), the active component of many insect repellents, is among the most frequently detected compounds in aqueous environments with concentrations reported in the ng L(-1) to μg L(-1) range. However, DEET is often detected in blanks and reported concentrations differ significantly depending on the analytical technique employed. In addition, relatively sparse data are available regarding the seasonal variability of DEET concentrations in water and there are apparent inconsistencies with expected use patterns. Therefore, the present study investigates potential interferences affecting the detection and quantification of DEET then the geographical and seasonal variations of DEET concentrations. To examine potential analytical interferences, DEET was analyzed in five geographically-diverse wastewater effluents using both gas chromatography and liquid chromatography coupled to mass spectrometric detectors. At times, the concentrations quantified by the employed analytical methods varied significantly. Five compounds with similar molecular weights and structures as DEET were investigated as potential mimics and some were shown to induce an overestimation of DEET. Further experimentation suggested that the solvents used in sample preparation and HPLC analysis are another possible source of interference. Besides potential interferences, the seven-month weekly monitoring of DEET in the primary effluent of a wastewater treatment plant demonstrated a clear seasonal trend with decreasing concentration from summer to winter. These data collectively demonstrate that there are many challenges in the quantification of DEET in complex environmental samples and that co-occurrence of similarly structured substances present in the water sample and/or the solvents used for the analysis could induce analytical bias.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
tert-Butyl methyl ether, anhydrous, 99.8%
Sigma-Aldrich
tert-Butyl methyl ether, reagent grade, 98%
Sigma-Aldrich
tert-Butyl methyl ether, suitable for HPLC, ≥99.8%
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
tert-Butyl methyl ether, ACS reagent, ≥99.0%
Supelco
tert-Butyl methyl ether, analytical standard
Sigma-Aldrich
tert-Butyl methyl ether, reagent grade, ≥98%
Supelco
tert-Butyl Methyl Ether, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
tert-Butyl methyl ether, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
tert-Butyl methyl ether, puriss. p.a., ≥99.5% (GC)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Supelco
Dichloromethane, analytical standard