Skip to Content
Merck
CN
  • Simultaneous quantification of seven hippocampal neurotransmitters in depression mice by LC-MS/MS.

Simultaneous quantification of seven hippocampal neurotransmitters in depression mice by LC-MS/MS.

Journal of neuroscience methods (2014-04-17)
Fei Huang, Jia Li, Hai-Lian Shi, Ting-ting Wang, Wahaf Muhtar, Min Du, Bei-bei Zhang, Hui Wu, Li Yang, Zhi-bi Hu, Xiao-jun Wu
ABSTRACT

There is no method available to simultaneously detect GABA, Glu, Epi, NE, DA, 5-HT and 5-HIAA in mouse hippocampus. A rapid and sensitive LC-MS/MS method has been developed for simultaneously measuring seven neurotransmitters in mouse hippocampus. The analytes were detected in positive mode with multiple reaction monitoring (MRM) and the procedure was completed in less than 9min. This method exhibited excellent linearity for all of the analytes with regression coefficients higher than 0.99, and showed good intra- and inter-day precisions (RSD<15%) with good accuracy (80-120%). Moreover, the method was successfully applied for the quantitative determination of neurotransmitters in a mouse depression model induced by successive methylprednisolone injections. The results indicated that this depression model was closely associated with the decreased level of Epi (p=0.002) and elevated ratio of 5-HIAA/5-HT (p=0.01), which has never been reported elsewhere. Compared with previous methods, current approach is more convenient without any pre-column derivatization of the analytes but enhances detectability with incremental neurotransmitter profile and shortens detection time. This work represents the first accurate simultaneous determination of seven neurotransmitters in the mouse depression model induced by methylprednisolone. The reliable method will benefit the research of neurological diseases with the altered neurotransmitter profile in brain.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Glutamic acid, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, analytical standard
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Serotonin creatinine sulfate monohydrate, powder
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)