Skip to Content
Merck
CN
  • Quantification of recombinant human erythropoietin by amino acid analysis using isotope dilution liquid chromatography-tandem mass spectrometry.

Quantification of recombinant human erythropoietin by amino acid analysis using isotope dilution liquid chromatography-tandem mass spectrometry.

Analytical and bioanalytical chemistry (2014-05-21)
Jung-Hyuk Yim, Ina Yoon, Hyo-Jin Yang, Sook-Kyung Kim, Sang-Ryoul Park, Yong-Moon Lee, Ji-Seon Jeong
ABSTRACT

Herein, we describe an accurate method for protein quantification based on conventional acid hydrolysis and an isotope dilution-ultra performance liquid chromatography-tandem mass spectrometry method. The analyte protein, recombinant human erythropoietin (rhEPO), was effectively hydrolyzed by incubation with 8 mol/L hydrochloric acid at 130 °C for 48 h, in which at least 1 μmol/kg of rhEPO was treated to avoid possible degradation of released amino acids during hydrolysis. Prior to hydrolysis, sample solution was subjected to ultrafiltration to eliminate potential interfering substances. In a reversed-phase column, the analytes (phenylalanine, proline, and valine) were separated within 3 min using gradient elution comprising 20 % (v/v) acetonitrile and 10 mmol/L ammonium acetate, both containing 0.3 % (v/v) trifluoroacetic acid. The optimized hydrolysis and analytical conditions in our study were strictly validated in terms of accuracy and precision, and were suitable for the accurate quantification of rhEPO. Certified rhEPO was analyzed using a conventional biochemical assay kit as an additional working calibrant for the quantification of EPO and improved the accuracy. The optimized protocol is suitable for the accurate quantification of rhEPO and satisfactorily serves as a reference analytical procedure for the certification of rhEPO and similar proteins.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Ammonium acetate solution, BioUltra, ~5 M in H2O
Sigma-Aldrich
Ammonium acetate, BioUltra, ≥99.0%
Sigma-Aldrich
L-Valine, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
L-Proline, BioUltra, ≥99.5% (NT)
SAFC
L-Proline
SAFC
L-Valine
Sigma-Aldrich
L-Proline, 99%, FCC, FG
Supelco
Ammonium acetate, LiChropur, eluent additive for LC-MS
Supelco
L-Valine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
L-Valine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
L-Proline, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
L-Valine, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
L-Valine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
L-Proline, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
L-Proline, from non-animal source, meets EP, USP testing specifications, suitable for cell culture
Sigma-Aldrich
Ammonium acetate solution, Molecular Biology, 7.5 M
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Ammonium acetate, Molecular Biology, ≥98%
Supelco
L-Proline, Pharmaceutical Secondary Standard; Certified Reference Material
Isoleucine, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ammonium acetate, Vetec, reagent grade, 97%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
L-Proline, Vetec, reagent grade, ≥99%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
USP
L-Proline, United States Pharmacopeia (USP) Reference Standard
Supelco
L-Phenylalanine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland