  • A sensitive and rapid HPLC-MS/MS method for the quantitative determination of trace amount of bromocriptine in small clinical prolactinoma tissue.

A sensitive and rapid HPLC-MS/MS method for the quantitative determination of trace amount of bromocriptine in small clinical prolactinoma tissue.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-03-31)
Qingce Zang, Yang Liu, Jiuming He, Xiaofei Yue, Ruiping Zhang, Renzhi Wang, Zeper Abliz
ABSTRACT

Usually, insufficient intratumoral concentration of therapeutic drugs is one of the reasons for tumor treatment failure. However, little is known about intratumoral distribution of bromocriptine in non-responding prolactinomas because of extremely low drug concentration and small prolactinoma tissue samples. In this study, a sensitive, rapid and high-throughput quantitative bioanalytical method has been established by using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) for the determination of bromocriptine at trace level in human prolactinoma tissue. As little as 20 mg (wet weight) tissue sample was required and total analysis time was 6 min in this method. The assay quantifies over a linear range of 50 fg/mg to 5 pg/mg, and has a 25 fg/mg limit of detection at a signal/noise ratio of 3. This validated method was successfully used to quantitatively determine bromocriptine in clinical post-operative bromocriptine-sensitive and -resistant prolactinomas. The results revealed bromocriptine concentration in resistant prolactinomas (0.49-1.25 pg/mg) was significantly higher than that in sensitive prolactinomas (0.057-0.47 pg/mg). These results provided direct evidence to demonstrate the reseaon for failure of bromocriptine treatment in some patients with prolactinoma was "intrinsic" tumor (cell) resistence, rather than insufficient drug concentration in tumor tissue. Additionaly, this HPLC-MS/MS method has been shown to be suitable for bromocriptine analysis in small amount tissue sample and could be adapted for therapeutic drug monitoring of other clinical medicine.

MATERIALS
Product Number
Brand
Product Description

Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Supelco
Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard