Skip to Content
Merck
CN
  • In vivo evaluation of different formulation strategies for sustained release injectables of a poorly soluble HIV protease inhibitor.

In vivo evaluation of different formulation strategies for sustained release injectables of a poorly soluble HIV protease inhibitor.

Journal of controlled release : official journal of the Controlled Release Society (2014-12-09)
Joke Meeus, David J Scurr, Katie Amssoms, Koen Wuyts, Pieter Annaert, Martyn C Davies, Clive J Roberts, Guy Van den Mooter
ABSTRACT

At present no scientific rationale exists for selecting a particular enabling strategy to formulate a poorly water-soluble drug, although this is crucial as it will influence the in vivo performance of the resulting formulation. This study provides an insight into this complicated decision making process for a poorly soluble human immunodeficiency virus (HIV) protease inhibitor based upon in vivo test results. A formulation strategy based on the molecular dispersion of this active pharmaceutical ingredient (API) into a biphasic matrix consisting of water-insoluble poly(lactic-co-glycolic acid) (PLGA) and water-soluble polyvinylpyrrolidone (PVP) was evaluated. The long-term in vivo performance of this strategy was compared to that of other solubility enhancing approaches by evaluating exposure of the API in male Beagle dogs. Solid dispersions, based on a PLGA/PVP matrix, were compared to solid dispersions in a pure PLGA matrix. Additionally these solid dispersion strategies were compared to the strategy of particle size reduction by means of an API microsuspension. The in vivo performance of the various formulations over a period of 28days after intramuscular injection was evaluated by the observed initial burst release, plasma concentration-time profiles, time at which maximum plasma levels were reached and the estimated bioavailability. Compared to the other formulation strategies assessed, it was concluded that the addition of PVP in a PLGA matrix resulted in vivo in a more sustained release as well as a higher amount of drug released from the polymeric matrix. This was explained based on the structure of these binary PLGA/PVP matrices where the pore network originating from rapidly dissolving PVP plays a key role. Moreover, the results suggest that the API release from this type of formulation could be delayed by increasing the amount of PLGA in the formulation.

MATERIALS
Product Number
Brand
Product Description

Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)