Merck
CN
  • Roles of inorganic oxide nanoparticles on extraction efficiency of electrospun polyethylene terephthalate nanocomposite as an unbreakable fiber coating.

Roles of inorganic oxide nanoparticles on extraction efficiency of electrospun polyethylene terephthalate nanocomposite as an unbreakable fiber coating.

Journal of chromatography. A (2014-12-17)
Habib Bagheri, Ali Roostaie
ABSTRACT

In the present work, the roles of inorganic oxide nanoparticles on the extraction efficiency of polyethylene terephthalate-based nanocomposites were extensively studied. Four fiber coatings based on polyethylene terephthalate nanocomposites containing different types of nanoparticles along with a pristine polyethylene terephthalate polymer were conveniently electrospun on stainless steel wires. The applicability of new fiber coatings were examined by headspace-solid phase microextraction of some environmentally important volatile organic compound such as benzene, toluene, ethylbenzene and xylene (BTEX), as model compounds, from aqueous samples. Subsequently, the extracted analytes were transferred into a gas chromatography by thermal desorption. Parameters affecting the morphology and capability of the prepared nanocomposites including the type of nanoparticles and their doping levels along with the coating time were optimized. Four types of nanoparticles including Fe3O4, SiO2, CoO and NiO were examined as the doping agents and among them the presence of SiO2 in the prepared nanocomposite was prominent. The homogeneity and the porous surface structure of the SiO2-polyethylene terephthalate nanocomposite were confirmed by scanning electron microscopy indicating that the nanofibers diameters were lower than 300 nm. In addition, important parameters influencing the extraction and desorption process such as temperature and extraction time, ionic strength and desorption conditions were optimized. Eventually, the developed method was validated by gas chromatography-mass spectrometry. Under optimized conditions, the relative standard deviation values for a double distilled water spiked with the selected volatile organic compounds at 50 ng L(-1) were 2-7% (n=3) while the limits of detection were between 0.7 and 0.9 ng L(-1). The method was linear in the concentration range of 10 to 1,000 ng L(-1) (R(2)>0.9992). Finally, the developed method was applied to the analysis of Kalan dam and tap water samples and the relative recovery values were found to be in the range of 86-102%.

MATERIALS
Product Number
Brand
Product Description

Supelco
Sodium chloride, reference material for titrimetry, certified by BAM, ≥99.5%
Supelco
Toluene, analytical standard
Sigma-Aldrich
Sodium hydroxide, BioUltra, for luminescence, ≥98.0% (T), pellets
Sigma-Aldrich
Sodium chloride, 99.999% trace metals basis
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Sigma-Aldrich
Sodium chloride, random crystals, optical grade, 99.9% trace metals basis
Sigma-Aldrich
Toluene, anhydrous, 99.8%
Sigma-Aldrich
Sodium chloride, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Supelco
SPME Portable Field Sampler, coating PDMS
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME Portable Field Sampler, coating PDMS/DVB
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 30 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME Sampling Stand, for use with 15 mL vials
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 30 μm(PDMS, needle size 24 ga, for use with autosampler
Sigma-Aldrich
3-Ethyl-2,4-pentanedione, mixture of tautomers, 98%
Sigma-Aldrich
m-Xylene, anhydrous, ≥99%
Sigma-Aldrich
Rhein, technical grade
Sigma-Aldrich
Toluene, JIS special grade, ≥99.5%
Supelco
SPME Portable Field Sampler, coating CAR/PDMS
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Sigma-Aldrich
Sodium chloride solution, 0.85%
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 23 ga, for use with autosampler