Skip to Content
Merck
CN
  • Multiple reaction monitoring with multistage fragmentation (MRM3) detection enhances selectivity for LC-MS/MS analysis of plasma free metanephrines.

Multiple reaction monitoring with multistage fragmentation (MRM3) detection enhances selectivity for LC-MS/MS analysis of plasma free metanephrines.

Clinical chemistry (2015-01-22)
Michael J Wright, Rebecca L Thomas, Phoebe E Stanford, Andrea R Horvath
ABSTRACT

LC-MS/MS with multiple reaction monitoring (MRM) is a powerful tool for quantifying target analytes in complex matrices. However, the technique lacks selectivity when plasma free metanephrines are measured. We propose the use of multistage fragmentation (MRM(3)) to improve the analytical selectivity of plasma free metanephrine measurement. Metanephrines were extracted from plasma with weak cation exchange solid-phase extraction before separation by hydrophilic interaction liquid chromatography. We quantified normetanephrine and metanephrine by either MRM or MRM(3) transitions m/z 166→134→79 and m/z 180→149→121, respectively. Over a 6-month period, approximately 1% (n = 21) of patient samples showed uncharacterized coeluting substances that interfered with the routine assay, resulting in an inability to report results. Quantification with MRM(3) removed these interferences and enabled measurement of the target compounds. For patient samples unaffected by interferences, Deming regression analysis demonstrated a correlation between MRM(3) and MRM methods of y = 1.00x - 0.00 nmol/L for normetanephrine and y = 0.99x + 0.03 nmol/L for metanephrine. Between the MRM(3) method and the median of all LC-MS/MS laboratories enrolled in a quality assurance program, the correlations were y = 0.97x + 0.03 nmol/L for normetanephrine and y = 1.03x - 0.04 nmol/L for metanephrine. Imprecision for the MRM(3) method was 6.2%-7.0% for normetanephrine and 6.1%-9.9% for metanephrine (n = 10). The lower limits of quantification for the MRM(3) method were 0.20 nmol/L for normetanephrine and 0.16 nmol/L for metanephrine. The use of MRM(3) technology improves the analytical selectivity of plasma free metanephrine quantification by LC-MS/MS while demonstrating sufficient analytical sensitivity and imprecision.

MATERIALS
Product Number
Brand
Product Description

Supelco
Hydrochloric acid solution, volumetric, 0.1 M HCl (0.1N), endotoxin free
Supelco
Hydrogen chloride – 2-propanol solution, ~1.25 M HCl (T), derivatization grade (GC derivatization), LiChropur
Supelco
Hydrogen chloride – ethanol, ~1.25 M HCl, derivatization grade (GC derivatization), LiChropur
Supelco
Hydrogen chloride – methanol solution, ~1.25 m HCl (T), derivatization grade (GC derivatization), LiChropur
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ammonium formate, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Supelco
Ammonium formate, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Ammonium formate, reagent grade, 97%
Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Sigma-Aldrich
Hydrogen chloride solution, 1.0 M in acetic acid
Sigma-Aldrich
Hydrochloric acid, ACS reagent, 37%
Sigma-Aldrich
Hydrochloric acid, puriss., 24.5-26.0%
Sigma-Aldrich
Hydrochloric acid, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
Hydrochloric acid solution, for amino acid analysis, ~6 M in H2O
Sigma-Aldrich
Hydrochloric acid, ACS reagent, 37%
Sigma-Aldrich
Hydrochloric acid solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Hydrochloric acid, 37 wt. % in H2O, 99.999% trace metals basis
Sigma-Aldrich
Hydrochloric acid, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., fuming, ≥37%, APHA: ≤10
Sigma-Aldrich
Hydrochloric acid, 36.5-38.0%, BioReagent, Molecular Biology
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%